Mô tả sản phẩm
Product portfolio
Performance
Measuring range |
200 mm … 10,000 mm, 90 % remission 200 mm … 6,000 mm, 18 % remission 200 mm … 4,000 mm, 6 % remission |
Target | Natural objects |
Resolution | 1 mm 1) |
Repeatability | ? 2.5 mm 2) 3) 4) |
Accuracy | ? 10 mm 1) 5) |
Response time | 10 ms … 50 ms, 10 ms / 50 ms 4) |
Switching frequency | 50 Hz / 10 Hz 4) |
Light source | Laser, red 6) |
Laser class | 2 (IEC 60825-1:2014, EN 60825-1:2014) 6) |
Typ. light spot size (distance) | 15 mm x 15 mm (10 m) |
Additional function | Set moving average: fast/slow, Set switching mode: Distance to object (DtO) / switching window (Wnd) / Object Between Sensor and Background (ObSB), teach-in, scaling and inversion of switching output, set hysteresis, Multifunctional input: laser off / external teach / deactivated, Unique measurement value, crosstalk safety, switch-off display, reset to factory default, lock user interface |
Average laser service life (at 25 ?C) | 100,000 h |
- 1) Related to distance value on the display.2) Equivalent to 1 ?.3) 6 % … 90 % remission.4) Dependent on the averaging setting: fast/slow.5) 90 % remission.6) Wavelength: 658 nm, max. output: 180 mW, pulse duration: 5 ns, duty cycle: 1/200.
Interfaces
Switching output | 2 x NPN (100 mA) 1) 2) |
Multifunctional input (MF) | 1 x 3) 4) |
Hysteresis | 1 mm … 9,999 mm |
- 1) Output Q short-circuit protected.2) NPN: HIGH = < 2.5 V / LOW = VS.3) Response time ? 60 ms.4) NPN: HIGH = ? 2.5 V / LOW = VS.
Mechanics/electronics
Supply voltage Vs | DC 10 V … 30 V 1) |
Ripple | ? 5 Vpp 2) |
Power consumption | ? 1.85 W 3) |
Initialization time | ? 350 ms |
Warm-up time | ? 15 min |
Housing material |
Housing zinc die cast (ZNAL4CU1) Acrylic glass (PMMA) |
Connection type | Male connector, M12, 5-pin |
Indication | LC display, 2 x LED |
Weight | 200 g |
Enclosure rating | IP65 |
Protection class | III |
- 1) Limit values, reverse-polarity protected, operation in short-circuit protected network: max. 8 A.2) May not fall short of or exceed VS tolerances.3) Without load.
Ambient data
Ambient temperature operation |
?30 ?C … +65 ?C ?30 ?C … +80 ?C, operation with 2 cooling plates ?30 ?C … +140 ?C, operation with 2 cooling plates and protection filter |
Ambient storage temperature | ?40 ?C … +75 ?C |
Max. rel. humidity (not condensing) | ? 95 % |
Typ. Ambient light immunity | 40,000 lx |
Vibration resistance | EN 60068-2-6, EN 60068-2-64 |
Shock resistance | EN 60068-2-27 |
Classifications
ECl@ss 5.0 | 27270801 |
ECl@ss 5.1.4 | 27270801 |
ECl@ss 6.0 | 27270801 |
ECl@ss 6.2 | 27270801 |
ECl@ss 7.0 | 27270801 |
ECl@ss 8.0 | 27270801 |
ECl@ss 8.1 | 27270801 |
ECl@ss 9.0 | 27270801 |
ETIM 5.0 | EC001825 |
ETIM 6.0 | EC001825 |
UNSPSC 16.0901 | 41111613 |