Mô tả sản phẩm
Photoelectric sensors
Features
Sensor/ detection principle | Through-beam photoelectric sensor |
Dimensions (W x H x D) | 12.2 mm x 41.8 mm x 17.3 mm |
Housing design (light emission) | Rectangular |
Sensing range max. | 0 m … 5 m |
Sensing range | 0 m … 4.5 m |
Type of light | Visible red light |
Light source | PinPoint LED 1) |
Light spot size (distance) | ? 50 mm (2 m) |
Wave length | 650 nm |
Adjustment | IO-Link |
Pin 2 configuration | External input, Teach-in input, Detection output, logic output, alarm output operating reserve |
Diagnosis | Status indicator operating reserve |
- 1) Average service life: 100,000 h at TU = +25 ?C.
Mechanics/electronics
Supply voltage | 10 V DC … 30 V DC 1) |
Ripple | < 5 Vpp 2) |
Power consumption |
20 mA 3) 20 mA 4) |
Switching output | PNP |
Switching mode | Light/dark switching |
Output current Imax. | ? 100 mA |
Response time Q/ on Pin 2 | 300 ?s … 450 ?s 5) 6) |
Switching frequency | 1,000 Hz |
Switching frequency Q / to pin 2 | 1,000 Hz 7) |
Connection type | Male connector M8, 4-pin |
Circuit protection |
A 8) B 9) C 10) D 11) |
Protection class | III |
Weight | 40 g |
IO-Link | ? |
Housing material | Plastic, ABS |
Optics material | Plastic, PMMA |
Enclosure rating |
IP67 IP66 |
Test input sender off | TE to 0 V |
Description | IO-Link, COM2, 2.3 ms, SIO mode |
Ambient operating temperature | ?40 ?C … +60 ?C |
Ambient storage temperature | ?40 ?C … +75 ?C |
UL File No. | NRKH.E181493 & NRKH7.E181493 |
Part number of individual components | 2073737 WS4S-3D2230 2073948 WE4SC-3P2230A00 |
Repeatability Q/ on Pin 2: | 150 ?s 6) |
- 1) Limit values when operated in short-circuit protected network: max. 8 A.2) May not exceed or fall below Uv tolerances.3) Sender.4) Receiver without load.5) Signal transit time with resistive load.6) Valid for Q on Pin2, if configured with software.7) With light / dark ratio 1:1, valid for Q on Pin2, if configured with software.8) A = VS connections reverse-polarity protected.9) B = inputs and output reverse-polarity protected.10) C = interference suppression.11) D = outputs overcurrent and short-circuit protected.
Classifications
ECl@ss 5.0 | 27270901 |
ECl@ss 5.1.4 | 27270901 |
ECl@ss 6.0 | 27270901 |
ECl@ss 6.2 | 27270901 |
ECl@ss 7.0 | 27270901 |
ECl@ss 8.0 | 27270901 |
ECl@ss 8.1 | 27270901 |
ECl@ss 9.0 | 27270901 |
ETIM 5.0 | EC002716 |
ETIM 6.0 | EC002716 |
UNSPSC 16.0901 | 39121528 |
Smart Task
Smart Task name | Base logics |
Logic function |
Direct AND OR WINDOW Hysteresis |
Timer function |
Deactivated On delay Off delay ON and OFF delay Impulse (one shot) |
Inverter | Yes |
Switching frequency |
SIO Direct: 1000 Hz SIO Logic: 1000 Hz IOL: 900 Hz |
Response time |
SIO Direct: 300 ?s … 450 ?s 1) SIO Logic: 500 ?s … 600 ?s 2) IOL: 500 ?s … 900 ?s 3) |
Repeatability |
SIO Direct: 150 ?s 1) SIO Logic: 150 ?s 2) IOL: 400 ?s 3) |
Switching signal QL1 | Switching output |
Switching signal QL2 | Switching output |
- 1) SIO Direct: sensor operation in standard I/O mode without IO-Link communication and without using internal sensor logic or time parameters (set to “direct”/”deactivated”).2) SIO Logic: Sensor operation in standard I/O mode without IO-Link communication. Sensor-internal logic or timing parameters plus Automation Functions used.3) IOL: Sensor operation with full IO-Link communication and usage of logic, timing and Automation Function parameters.
Communication interface
Communication interface | IO-Link V1.1 |
Communication Interface detail | COM2 (38,4 kBaud) |
Cycle time | 2.3 ms |
Process data length | 16 Bit |
Process data structure |
Bit 0 = switching signal QL1 Bit 1 = switching signal QL2 Bit 2 … 15 = empty |