HTB18-A1G2BB

4,772,000

Tên sản phẩm: Hybrid photoelectric sensors SureSense

Danh mục: Photoelectric sensors

Model: HTB18-A1G2BB

ID: 1078525

Nhà sản xuất: SICK

Xuất xứ:

Hàng mới 100%, bảo hành 12 tháng theo quy định nhà sản xuất

Cung cấp chứng nhận xuất xứ (CO), chứng nhận chất lượng (CQ) theo yêu cầu khách hàng

Mã: 1078525 Danh mục:

Mô tả sản phẩm

Photoelectric sensors

Features
Sensor/ detection principle Photoelectric proximity sensor, Background suppression
Dimensions (W x H x D) 16.2 mm x 45.5 mm x 31.8 mm
Housing design (light emission) Hybrid
Thread diameter (housing) M18
Mounting system type M18, nose / side (24 ? 24.5 mm)
Housing color Blue
Sensing range max. 5 mm … 300 mm 1)
Sensing range 5 mm … 150 mm 2)
Type of light Visible red light
Light source PinPoint LED 3)
Light spot size (distance) 7 mm (300 mm)
Wave length 631 nm
Adjustment
Potentiometer, right Sensing range
Potentiometer, left None
Special features Signal strength light bar
    1) Object with 90 % reflectance (referred to standard white, DIN 5033).2) Object with 6 % reflectance (referred to standard black, DIN 5033).3) Average service life: 100,000 h at TU = +25 ?C.
Mechanics/electronics
Supply voltage 10 V DC … 30 V DC
Ripple < 5 Vpp 1)
Power consumption 20 mA 2)
Switching output

PNP

NPN

Switching output detail
Switching output Q1 PNP, Dark switching
Switching output Q2 NPN, Dark switching
Output current Imax. ? 100 mA
Response time ? 0.5 ms 3)
Switching frequency 1,000 Hz 4)
Connection type Cable open end, 2,000 mm
Cable material PVC
Conductor cross-section 0.2 mm?
Circuit protection

A 5)

B 6)

D 7)

Protection class III 8)
Weight 18 g
Housing material Plastic, VISTAL?
Optics material Plastic, PMMA
Enclosure rating

IP67

IP69K

EMC EN 60947-5-2 (The sensor complies with the Radio Safety Requirements (EMC) for the industrial sector (Radio Safety Class A). It may cause radio interference if used in a residential area.)
Ambient operating temperature ?40 ?C … +65 ?C
Ambient storage temperature ?40 ?C … +75 ?C
UL File No. E189383
    1) May not exceed or fall below Uv tolerances.2) Without signal strength light bar and load.3) Signal transit time with resistive load.4) With light/dark ratio 1:1.5) A = VS connections reverse-polarity protected.6) B = inputs and output reverse-polarity protected.7) D = outputs overcurrent and short-circuit protected.8) Reference voltage: 50 V DC.
Classifications
ECl@ss 5.0 27270904
ECl@ss 5.1.4 27270904
ECl@ss 6.0 27270904
ECl@ss 6.2 27270904
ECl@ss 7.0 27270904
ECl@ss 8.0 27270904
ECl@ss 8.1 27270904
ECl@ss 9.0 27270904
ETIM 5.0 EC002719
ETIM 6.0 EC002719
UNSPSC 16.0901 39121528