WL4SLC-3P2232A70

7,568,000

Tên sản phẩm: Miniature photoelectric sensors W4SL-3

Danh mục: Photoelectric sensors

Model: WL4SLC-3P2232A70

ID: 1080947

Nhà sản xuất: SICK

Xuất xứ: DE

Hàng mới 100%, bảo hành 12 tháng theo quy định nhà sản xuất

Cung cấp chứng nhận xuất xứ (CO), chứng nhận chất lượng (CQ) theo yêu cầu khách hàng

Mã: 1080947 Danh mục:

Mô tả sản phẩm

Photoelectric sensors

Features
Sensor/ detection principle Photoelectric retro-reflective sensor, autocollimation
Dimensions (W x H x D) 12.2 mm x 41.8 mm x 17.3 mm
Housing design (light emission) Rectangular
Mounting hole M3
Sensing range max. 0 m … 12 m 1)
Sensing range 0 m … 8 m 1)
Type of light Visible red light
Light source Laser 2)
Light spot size (distance) ? 1 mm (500 mm)
Wave length 650 nm
Laser class 1 (EN 60825-1:2014, IEC 60825-1:2014 / CDRH 21 CFR 1040.10 & 1040.11)
Adjustment

IO-Link

Single teach-in button

Pin 2 configuration External input, Teach-in input, Sender off input, Detection output, logic output, Device contamination alarm output
Diagnosis Device contamination monitoring, Quality of teach-in
Special applications Detecting small objects
    1) Reflector PL80A.2) Average service life: 50,000 h at TU = +25 ?C.
Mechanics/electronics
Supply voltage 10 V DC … 30 V DC 1)
Ripple < 5 Vpp 2)
Power consumption 30 mA 3)
Switching output PNP 4)
Output function Complementary
Switching mode Light/dark switching 4)
Output current Imax. ? 100 mA
Response time ? 0.5 ms 5)
Response time Q/ on Pin 2 300 ?s … 450 ?s 5) 6)
Switching frequency 1,000 Hz 7)
Switching frequency Q / to pin 2 1,000 Hz 8)
Connection type Male connector M8, 4-pin
Circuit protection

A 9)

B 10)

C 11)

Protection class III
Weight 100 g
Polarisation filter ?
Housing material Plastic, Novodur
Optics material Plastic, PMMA
Enclosure rating

IP66

IP67

Ambient operating temperature ?10 ?C … +50 ?C
Ambient operating temperature extended ?30 ?C … +55 ?C 12) 13)
Ambient storage temperature ?30 ?C … +70 ?C
MTTFd: mean time to dangerous failure 723 years (EN ISO 13849-1) 14)
UL File No. NRKH.E181493
Repeatability Q/ on Pin 2: 150 ?s 6)
    1) Limit values when operated in short-circuit protected network: max. 8 A.2) May not exceed or fall below Uv tolerances.3) Without load.4) Q = light switching.5) Signal transit time with resistive load.6) Valid for Q on Pin2, if configured with software.7) With light/dark ratio 1:1.8) With light / dark ratio 1:1, valid for Q on Pin2, if configured with software.9) A = VS connections reverse-polarity protected.10) B = inputs and output reverse-polarity protected.11) C = interference suppression.12) As of Ta = 50 ?C, a max. supply voltage Vmax. = 24 V and a max. load current Imax. = 50 mA is permitted.13) Operation below Tu ?10 ?C is possible if the sensor is already switched on at Tu > ?10 ?C, then cools down, and the supply voltage is subsequently not switched off. Switching on below Tu ?10 ?C is not permissible.14) Mode of calculation: Parts-Count-calculation.
Classifications
ECl@ss 5.0 27270902
ECl@ss 5.1.4 27270902
ECl@ss 6.0 27270902
ECl@ss 6.2 27270902
ECl@ss 7.0 27270902
ECl@ss 8.0 27270902
ECl@ss 8.1 27270902
ECl@ss 9.0 27270902
ETIM 5.0 EC002717
ETIM 6.0 EC002717
UNSPSC 16.0901 39121528
Smart Task
Smart Task name Time measurement + debouncing
Logic function

Direct

WINDOW

Timer function

Deactivated

On delay

Off delay

ON and OFF delay

Impulse (one shot)

Inverter Yes
Time measurement accuracy

SIO Direct: — 1)

SIO Logic: – 0,7 … + 0,7 ms ? 0,5 % of time measurement value 2)

IOL: – 0.9 … + 0.9 ms ? 0.5% of the time measurement 3)

Time measurement accuracy (e.g. accuracy for time measurement value = 1 s )

SIO Direct: — 1)

SIO Logic: – 5,7 … + 5,7 ms 2)

IOL: – 5,9 … + 5,9 ms 3)

Resolution time measuring value 1 ms
Min. Time between two process events (switches)

SIO Direct: —

SIO Logic: 450 ?s

IOL: 500 ?s

Debounce time max.

SIO Direct: — 1)

SIO Logic: 30.000 ms 2)

IOL: 30.000 ms 3)

Switching signal QL1 Output type (dependant on the adjusted threshold)
Switching signal QL2 Output type (dependant on the adjusted threshold)
Measuring value Time measurement value
    1) SIO Direct: sensor operation in standard I/O mode without IO-Link communication and without using internal sensor logic or time parameters (set to “direct”/”deactivated”).2) SIO Logic: Sensor operation in standard I/O mode without IO-Link communication. Sensor-internal logic or timing parameters plus Automation Functions used.3) IOL: Sensor operation with full IO-Link communication and usage of logic, timing and Automation Function parameters.
Communication interface
Communication interface IO-Link V1.1
Communication Interface detail COM2 (38,4 kBaud)
Cycle time 2.3 ms
Process data length 16 Bit
Process data structure

Bit 0 = switching signal QL1

Bit 1 = switching signal QL2

Bit 2 … 15 = measuring value