WSE4SLC-3P2236A71

9,333,000

Tên sản phẩm: Miniature photoelectric sensors W4SL-3

Danh mục: Photoelectric sensors

Model: WSE4SLC-3P2236A71

ID: 1080961

Nhà sản xuất: SICK

Xuất xứ: DE

Hàng mới 100%, bảo hành 12 tháng theo quy định nhà sản xuất

Cung cấp chứng nhận xuất xứ (CO), chứng nhận chất lượng (CQ) theo yêu cầu khách hàng

Mã: 1080961 Danh mục:

Mô tả sản phẩm

Photoelectric sensors

Features
Sensor/ detection principle Through-beam photoelectric sensor
Dimensions (W x H x D) 12.2 mm x 41.8 mm x 17.3 mm
Housing design (light emission) Rectangular
Mounting hole M3
Sensing range max. 0 m … 60 m
Sensing range 0 m … 50 m
Type of light Visible red light
Light source Laser 1)
Light spot size (distance) ? 1 mm (500 mm)
Wave length 650 nm
Laser class 1 (EN 60825-1:2014, IEC 60825-1:2014 / CDRH 21 CFR 1040.10 & 1040.11)
Adjustment IO-Link
Pin 2 configuration External input, Detection output, logic output, Alarm output
Diagnosis Status indicator operating reserve
Special applications Detecting small objects
    1) Average service life: 50,000 h at TU = +25 ?C.
Mechanics/electronics
Supply voltage 10 V DC … 30 V DC 1)
Ripple < 5 Vpp 2)
Power consumption 30 mA 3)
Switching output PNP 4)
Output function Complementary
Switching mode Light/dark switching 4)
Output current Imax. ? 100 mA
Response time ? 0.5 ms 5)
Switching frequency 1,000 Hz 6)
Switching frequency Q / to pin 2 1,000 Hz 7)
Connection type Male connector M8, 4-pin
Circuit protection

A 8)

B 9)

C 10)

Protection class III
Weight 100 g
Housing material Plastic, Novodur
Optics material Plastic, PMMA
Enclosure rating

IP66

IP67

Ambient operating temperature ?10 ?C … +50 ?C
Ambient operating temperature extended ?30 ?C … +55 ?C 11) 12)
Ambient storage temperature ?30 ?C … +70 ?C
MTTFd: mean time to dangerous failure 355 years (EN ISO 13849-1) 13)
Part number of individual components 2064095 WS4SL-3D2236, 2088186 WE4SLC-3P2230A71
Repeatability Q/ on Pin 2: 150 ?s 14)
    1) Limit values when operated in short-circuit protected network: max. 8 A.2) May not exceed or fall below Uv tolerances.3) Without load.4) Q = light switching.5) Signal transit time with resistive load.6) With light/dark ratio 1:1.7) With light / dark ratio 1:1, valid for Q on Pin2, if configured with software.8) A = VS connections reverse-polarity protected.9) B = inputs and output reverse-polarity protected.10) C = interference suppression.11) As of Ta = 50 ?C, a max. supply voltage Vmax. = 24 V and a max. load current Imax. = 50 mA is permitted.12) Operation below Tu ?10 ?C is possible if the sensor is already switched on at Tu > ?10 ?C, then cools down, and the supply voltage is subsequently not switched off. Switching on below Tu ?10 ?C is not permissible.13) Mode of calculation: Parts-Count-calculation.14) Valid for Q on Pin2, if configured with software.
Classifications
ECl@ss 5.0 27270901
ECl@ss 5.1.4 27270901
ECl@ss 6.0 27270901
ECl@ss 6.2 27270901
ECl@ss 7.0 27270901
ECl@ss 8.0 27270901
ECl@ss 8.1 27270901
ECl@ss 9.0 27270901
ETIM 5.0 EC002716
ETIM 6.0 EC002716
UNSPSC 16.0901 39121528
Smart Task
Smart Task name Counter + debouncing
Logic function

Direct

WINDOW

Hysteresis

Timer function

Deactivated

On delay

Off delay

ON and OFF delay

Impulse (one shot)

Inverter Yes
Maximum counting frequency

SIO Direct: — 1)

SIO Logic: 1000 Hz 2)

IOL: 900 Hz 3)

Counter reset

SIO Direct: —

SIO Logic: 1,5 ms

IOL: 1,5 ms

Min. Time between two process events (switches)

SIO Direct: —

SIO Logic: 450 ?s

IOL: 500 ?s

Debounce time max.

SIO Direct: —

SIO Logic: 30.000 ms

IOL: 30.000 ms

Switching signal QL1 Output type (dependant on the adjusted threshold)
Switching signal QL2 Output type (dependant on the adjusted threshold)
Measuring value Counting value
    1) SIO Direct: sensor operation in standard I/O mode without IO-Link communication and without using internal sensor logic or time parameters (set to “direct”/”deactivated”).2) SIO Logic: Sensor operation in standard I/O mode without IO-Link communication. Sensor-internal logic or timing parameters plus Automation Functions used.3) IOL: Sensor operation with full IO-Link communication and usage of logic, timing and Automation Function parameters.
Communication interface
Communication interface IO-Link V1.1
Communication Interface detail COM2 (38,4 kBaud)
Cycle time 2.3 ms
Process data length 16 Bit
Process data structure

Bit 0 = switching signal QL1

Bit 1 = switching signal QL2

Bit 2 … 15 = measuring value