Mô tả sản phẩm
Encoders
Features
Special device | ? |
Specialty | Customized resistance of vibration values, No default name in state upon delivery |
Standard reference device | AFM60A-S4IB018X12, 1055334 |
Performance
Number of steps per revolution | 262,144 (max.) |
Number of revolutions | 4,096 (max.) |
Resolution | 18 bit x 12 bit |
Error limits G | 0.03? 1) |
Repeatability standard deviation ?r | 0.002? 2) |
- 1) In accordance with DIN ISO 1319-1, position of the upper and lower error limit depends on the installation situation, specified value refers to a symmetrical position, i.e. deviation in upper and lower direction is the same.2) In accordance with DIN ISO 55350-13, 68.3% of the measured values are inside the specified area.
Interfaces
Communication interface | EtherNet/IP? |
Encoder profile | 0 x 22 |
Data transmission rate (baud rate) |
10 Mbit/s 100 Mbit/s |
Transmission medium | CAT-5e cable |
Parameterising data | Number of steps per revolution, number of revolutions, PRESET, counting direction, sampling rate for speed monitoring, unit for outputting the speed, acceleration, and temperature, output of scaleable limit values such as: position ranges, speed, acceleration, number of movements cw/ccw, direction chances, operating hours for power-on/motion, round axis functionality (only multiturn version), heartbeat |
RPI (requested packet interval) | 5 ms … 750 ms |
DLR (Device Level Ring) | ? |
Available diagnostics data | Current, minimum and maximum temperature, maximum speed, power-on counter, operating hours counter for power-on/motion, counter of direction changes/number of movements cw/number of movements ccw, minimum and maximum operating voltage, signal monitoring for single and multiturn |
Initialization time | Approx. 12 s |
Electrical data
Connection type | Male connector, 3 x M12, 4-pin, axial |
Supply voltage range | 10 V DC … 30 V DC |
Reverse polarity protection | ? |
MTTFd: mean time to dangerous failure | 80 years (EN ISO 13849-1) 1) |
- 1) This product is a standard product and does not constitute a safety component as defined in the Machinery Directive. Calculation based on nominal load of components, average ambient temperature 40?C, frequency of use 8760 h/a. All electronic failures are considered hazardous. For more information, see document no. 8015532.
Mechanical data
Mechanical design | Solid shaft, face mount flange |
Shaft diameter | 10 mm x 19 mm |
Shaft length | 19 mm |
Weight | 0.2 kg |
Shaft material | Stainless steel |
Flange material | Aluminum |
Housing material | Aluminum |
Start up torque | 0.5 Ncm |
Operating torque | 0.3 Ncm |
Permissible Load capacity of shaft |
80 N / radial 40 N / axial |
Moment of inertia of the rotor | 6.2 gcm? |
Bearing lifetime | 3.0 x 10^9 revolutions |
Angular acceleration | ? 500,000 rad/s? |
Ambient data
EMC | According to EN 61000-6-2 and EN 61000-6-3 1) |
Enclosure rating |
IP65, shaft side (according to IEC 60529) IP67, housing side (according to IEC 60529) 2) |
Permissible relative humidity | 90 % (condensation of the optical scanning not permitted) |
Operating temperature range | ?40 ?C … +85 ?C |
Storage temperature range | ?40 ?C … +100 ?C, without package |
Resistance to shocks | 100 g, 6 ms (according to EN 60068-2-27) |
Resistance to vibration | 15 g, 10 Hz … 2,000 Hz (according to EN 60068-2-6) |
- 1) EMC according to the standards quoted is achieved if shielded cables are used.2) With mating connector fitted.
Classifications
ECl@ss 5.0 | 27270502 |
ECl@ss 5.1.4 | 27270502 |
ECl@ss 6.0 | 27270590 |
ECl@ss 6.2 | 27270590 |
ECl@ss 7.0 | 27270502 |
ECl@ss 8.0 | 27270502 |
ECl@ss 8.1 | 27270502 |
ECl@ss 9.0 | 27270502 |
ETIM 5.0 | EC001486 |
ETIM 6.0 | EC001486 |
UNSPSC 16.0901 | 41112113 |