GRTE18-P1162V

3,404,000

Tên sản phẩm: Cylindrical photoelectric sensors GR18 Inox

Danh mục: Photoelectric sensors

Model: GRTE18-P1162V

ID: 1085705

Nhà sản xuất: SICK

Xuất xứ: MY

Hàng mới 100%, bảo hành 12 tháng theo quy định nhà sản xuất

Cung cấp chứng nhận xuất xứ (CO), chứng nhận chất lượng (CQ) theo yêu cầu khách hàng

Mã: 1085705 Danh mục:

Mô tả sản phẩm

Photoelectric sensors

Features
Sensor/ detection principle Photoelectric proximity sensor, Energetic
Housing design (light emission) Cylindrical
Housing length 73.5 mm
Thread length 49.3 mm
Thread diameter (housing) M18 x 1
Optical axis Axial
Sensing range max. 5 mm … 1,000 mm 1)
Sensing range 10 mm … 800 mm 1)
Type of light Visible red light
Light source LED 2)
Light spot size (distance) ? 45 mm (800 mm)
Wave length 650 nm
Adjustment Potentiometer, 270?
Special applications Hygienic and washdown zones
    1) Object with 90 % reflectance (referred to standard white, DIN 5033).2) Average service life: 100,000 h at TU = +25 ?C.
Mechanics/electronics
Supply voltage 10 V DC … 30 V DC 1)
Ripple ? 5 Vpp 2)
Power consumption 30 mA
Switching output PNP
Output function Complementary
Switching mode Light/dark switching 3)
Signal voltage PNP HIGH/LOW VS – (? 3 V) / approx. 0 V
Output current Imax. 100 mA 4)
Response time < 1,000 ?s 5)
Switching frequency ? 500 Hz 6)
Connection type Cable, 4-wire, 2 m 7)
Cable material PVC
Conductor cross-section 0.14 mm?
Cable diameter 4.8 mm
Circuit protection

A 8)

B 9)

D 10)

Protection class III
Weight 175 g
Housing material Stainless steel, Stainless steel V4A (1.4404, 316L)
Optics material Plastic, PMMA
Tightening torque, max. 90 Nm
Enclosure rating

IP67

IP68 11)

IP69K 12)

Items supplied Fastening nuts (2 x)
EMC EN 60947-5-2
Ambient operating temperature ?25 ?C … +55 ?C 13)
Ambient storage temperature ?30 ?C … +75 ?C
UL File No. E348498
    1) Limit values. Operated in short-circuit protected network: max. 8 A.2) May not exceed or fall below Uv tolerances.3) Q = light switching, ? = dark switching.4) At Uv > 24 V or ambient temperature > 49 ?C, IA max. = 50 mA.5) Signal transit time with resistive load.6) With light/dark ratio 1:1.7) Do not bend below 0 ?C.8) A = VS connections reverse-polarity protected.9) B = inputs and output reverse-polarity protected.10) D = outputs overcurrent and short-circuit protected.11) According to EN 60529 (10 m water depth / 24 h).12) According to ISO 20653:2013-03.13) At Uv <=24V and IA<50mA.
Classifications
ECl@ss 5.0 27270903
ECl@ss 5.1.4 27270903
ECl@ss 6.0 27270903
ECl@ss 6.2 27270903
ECl@ss 7.0 27270903
ECl@ss 8.0 27270903
ECl@ss 8.1 27270903
ECl@ss 9.0 27270903
ETIM 5.0 EC001821
ETIM 6.0 EC001821
UNSPSC 16.0901 39121528