Mô tả sản phẩm
Photoelectric sensors
Features
Sensor/ detection principle | Photoelectric retro-reflective sensor, autocollimation |
Dimensions (W x H x D) | 15.25 mm x 49.2 mm x 22.2 mm |
Housing design | Washdown |
Housing design (light emission) | Rectangular |
Sensing range max. | 0 m … 5 m 1) |
Sensing range | 0 m … 3 m 1) |
Type of light | Visible red light |
Light source | PinPoint LED 2) |
Light spot size (distance) | ? 45 mm (1.5 m) |
Wave length | 650 nm |
Adjustment | Single teach-in button |
AutoAdapt | ? |
Special applications | Hygienic and washdown zones, Detecting transparent objects |
- 1) Reflector PL80A.2) Average service life: 100,000 h at TU = +25 ?C.
Mechanics/electronics
Supply voltage | 10 V DC … 30 V DC 1) |
Ripple | < 5 Vpp 2) |
Power consumption | 30 mA 3) |
Switching output | PNP |
Output function | Complementary |
Switching mode | Light/dark switching |
Output current Imax. | ? 100 mA |
Response time | < 0.5 ms 4) |
Switching frequency | 1,000 Hz 5) |
Connection type | Male connector M12, 4-pin 6) 7) |
Cable material | PVC |
Circuit protection | A, B, C 10) 8) 9) |
Protection class | III |
Weight | 45 g |
Polarisation filter | ? |
IO-Link | ? |
Housing material | Stainless steel, stainless steel 316L |
Enclosure rating | IP66, IP67, IP68, IP69K |
Special feature | Detecting transparent objects |
Ambient operating temperature |
?30 ?C … +70 ?C 11) ?30 ?C … +60 ?C |
Ambient storage temperature | ?30 ?C … +75 ?C |
UL File No. | NRKH.E181493 & NRKH7.E181493 |
- 1) Limit values, reverse-polarity protected, operation in short-circuit protected network: max. 8 A.2) May not exceed or fall below Uv tolerances.3) Without load.4) Signal transit time with resistive load.5) With light/dark ratio 1:1.6) Max. tightening torque: 0.7 Nm.7) Do not bend below 0 ?C.8) A = VS connections reverse-polarity protected.9) B = inputs and output reverse-polarity protected.10) C = interference suppression.11) At UV ? 24 V and IA < 30 mA.
Classifications
ECl@ss 5.0 | 27270902 |
ECl@ss 5.1.4 | 27270902 |
ECl@ss 6.0 | 27270902 |
ECl@ss 6.2 | 27270902 |
ECl@ss 7.0 | 27270902 |
ECl@ss 8.0 | 27270902 |
ECl@ss 8.1 | 27270902 |
ECl@ss 9.0 | 27270902 |
ETIM 5.0 | EC002717 |
ETIM 6.0 | EC002717 |
UNSPSC 16.0901 | 39121528 |
Smart Task
Smart Task name | Base logics |
Logic function |
Direct AND OR WINDOW Hysteresis |
Timer function |
Deactivated On delay Off delay ON and OFF delay Impulse (one shot) |
Inverter | Yes |
Switching frequency |
SIO Direct: 1000 Hz SIO Logic: 1000 Hz IOL: 900 Hz |
Response time |
SIO Direct: 300 ?s … 450 ?s 1) SIO Logic: 500 ?s … 600 ?s 2) IOL: 500 ?s … 900 ?s 3) |
Repeatability |
SIO Direct: 150 ?s 1) SIO Logic: 150 ?s 2) IOL: 400 ?s 3) |
Switching signal QL1 | Switching output |
Switching signal QL2 | Switching output |
- 1) SIO Direct: sensor operation in standard I/O mode without IO-Link communication and without using internal sensor logic or time parameters (set to “direct”/”deactivated”).2) SIO Logic: Sensor operation in standard I/O mode without IO-Link communication. Sensor-internal logic or timing parameters plus Automation Functions used.3) IOL: Sensor operation with full IO-Link communication and usage of logic, timing and Automation Function parameters.
Communication interface
Communication interface | IO-Link V1.1 |
Communication Interface detail | COM2 (38,4 kBaud) |
Cycle time | 2.3 ms |
Process data length | 16 Bit |
Process data structure |
Bit 0 = switching signal QL1 Bit 1 = switching signal QL2 Bit 2 … 15 = empty |