Mô tả sản phẩm
Photoelectric sensors
Sensor/ detection principle | Photoelectric proximity sensor, LineSpot technology, Background suppression |
Dimensions (W x H x D) | 20 mm x 55.7 mm x 42 mm |
Housing design (light emission) | Rectangular |
Sensing range max. | 10 mm … 500 mm 1) |
Type of light | Visible red light |
Light source | PinPoint LED 2) |
Light spot size (distance) | 3 mm x 30 mm (200 mm) |
Wave length | 635 nm |
Adjustment |
BluePilot: Teach-Turn adjustment with sensing range indicator IO-Link |
Pin 2 configuration | External input, Teach-in, switching signal |
Special applications | Detecting perforated objects |
Special features | Line-shaped light spot |
- 1) Object with 90 % reflectance (referred to standard white, DIN 5033).2) Average service life: 100,000 h at TU = +25 ?C.
Supply voltage | 10 V DC … 30 V DC 1) |
Ripple | ? 5 Vpp |
Power consumption |
30 mA 2) 50 mA 3) |
Switching output |
PUSH/PULL PNP NPN |
Output: QL1 / C | Switching output or IO-Link mode |
Output function | Factory setting: Pin 2 (MF): NPN normally open (light switching), PNP normally closed (dark switching), Pin 4 (QL1/C): NPN normally closed (dark switching), PNP normally open (light switching), IO-Link |
Switching mode | Light/dark switching |
Signal voltage PNP HIGH/LOW | Approx. VS ? 2.5 V / 0 V |
Signal voltage NPN HIGH/LOW | Approx. VS / < 2.5 V |
Output current Imax. | ? 100 mA |
Response time | ? 500 ?s 4) |
Switching frequency | 1,000 Hz 5) |
Connection type | Male connector M12, 4-pin |
Circuit protection |
A 6) B 7) C 8) D 9) |
Protection class | III |
Weight | 50 g |
IO-Link | ? |
Housing material | Plastic, VISTAL? |
Optics material | Plastic, PMMA |
Enclosure rating |
IP66 IP67 |
Ambient operating temperature | ?40 ?C … +60 ?C |
Ambient storage temperature | ?40 ?C … +75 ?C |
MTTFd: mean time to dangerous failure | 629 years |
UL File No. | NRKH.E181493 & NRKH7.E181493 |
- 1) Limit values.2) 16 V DC … 30 V DC, without load.3) 10 V DC … 16 V DC, without load.4) Signal transit time with resistive load in switching mode. Different values possible in COM2 mode.5) With light/dark ratio 1:1 in switching mode. Different values possible in IO-Link mode.6) A = VS connections reverse-polarity protected.7) B = inputs and output reverse-polarity protected.8) C = interference suppression.9) D = outputs overcurrent and short-circuit protected.
ECl@ss 5.0 | 27270904 |
ECl@ss 5.1.4 | 27270904 |
ECl@ss 6.0 | 27270904 |
ECl@ss 6.2 | 27270904 |
ECl@ss 7.0 | 27270904 |
ECl@ss 8.0 | 27270904 |
ECl@ss 8.1 | 27270904 |
ECl@ss 9.0 | 27270904 |
ETIM 5.0 | EC002719 |
ETIM 6.0 | EC002719 |
UNSPSC 16.0901 | 39121528 |
Smart Task name | Base logics |
Logic function |
Direct AND OR Window Hysteresis |
Timer function |
Deactivated On delay Off delay ON and OFF delay Impulse (one shot) |
Inverter | Yes |
Switching frequency |
SIO Direct: 1000 Hz 1) SIO Logic: 800 Hz 2) IOL: 650 Hz 3) |
Response time |
SIO Direct: 500 ?s 1) SIO Logic: 600 ?s 2) IOL: 750 ?s 3) |
Repeatability |
SIO Direct: 150 ?s 1) SIO Logic: 300 ?s 2) IOL: 400 ?s 3) |
Switching signal QL1 | Switching output |
Switching signal QL2 | Switching output |
- 1) SIO Direct: sensor operation in standard I/O mode without IO-Link communication and without using internal sensor logic or time parameters (set to “direct”/”deactivated”).2) SIO Logic: Sensor operation in standard I/O mode without IO-Link communication. Sensor-internal logic or timing parameters plus Automation Functions used.3) IOL: Sensor operation with full IO-Link communication and usage of logic, timing and Automation Function parameters.
Communication interface | IO-Link V1.1 |
Communication Interface detail | COM2 (38,4 kBaud) |
Cycle time | 2.3 ms |
Process data length | 16 Bit |
Process data structure |
Bit 0 = switching signal QL1 Bit 1 = switching signal QL2 Bit 2 … 15 = empty |
VendorID | 26 |
DeviceID HEX | 0x800168 |
DeviceID DEZ | 8388968 |