Mô tả sản phẩm
Product portfolio
Features
Protective field range | 2 m |
Warning field range | 8 m (at 15 % reflectivity) |
Distance measuring range | 30 m |
Type of field set | Triple field sets |
Number of field sets | 8 |
Number of fields | 24 |
Number of monitoring cases | 32 1) |
Scanning angle | 270? |
Resolution (can be configured) | 30 mm, 40 mm, 50 mm, 70 mm |
Angular resolution | 0.5? |
Response time | 80 ms 2) |
Protective field supplement | 100 mm |
Number of multiple samplings | 2 … 16, configurable |
Delay of automatic reset | 2 s … 60 s, configurable |
- 1) In combination with an additional static input via EFI or using the dynamic inputs on the device. Otherwise eight.2) Depending on basic response time and multiple sampling.
Safety-related parameters
Type | Type 3 (IEC 61496) |
Safety integrity level |
SIL2 (IEC 61508) SILCL2 (EN 62061) |
Category | Category 3 (EN ISO 13849) |
Performance level | PL d (EN ISO 13849) |
PFHD (mean probability of a dangerous failure per hour) | 8.0 x 10-8 (EN ISO 13849) |
TM (mission time) | 20 years (EN ISO 13849) |
Safe state in the event of a fault | At least one OSSD is in the OFF state. |
Functions
Restart interlock | ? |
External device monitoring (EDM) | ? |
Multiple sampling | ? |
Monitoring case switching | ? |
Static protective field switching | ? |
Dynamic protective field switching | ? |
Contour as a reference | ? |
Integrated configuration memory | ? |
Measured data output | ? |
Safe SICK device communication via EFI | ? |
Interfaces
|
|||||||||||||||
Universal I/Os? | 5 1) | ||||||||||||||
|
|||||||||||||||
|
|||||||||||||||
Configuration method | PC with CDS (Configuration and Diagnostic Software) | ||||||||||||||
|
|||||||||||||||
|
|||||||||||||||
|
|||||||||||||||
|
- 1) Freely programmable, e.g., external device monitoring input, reset input, contamination warning, reset required.2) Availability depends on the configuration of the universal I/Os.3) 2+1, additional input is only available if reset and reset required are not being used.4) In combination with an EFI device (Flexi Soft or EFI gateway) five static control inputs are available. Otherwise three.5) Two of the static swichting signals can be used either as dynamic or as static switching signals.6) Freely programmable, e.g. warning field, contamination, reset required.7) For a suitable EFI-gateway see modules and gateways in the accessory section of connection systems.
Electrical data
Protection class | II (EN 50178, EN 60950) | ||||||
Supply voltage Vs | 24 V DC (16.8 V DC … 30 V DC) | ||||||
Power consumption |
? 0.33 A 1) ? 1.7 A 2) |
||||||
|
- 1) At 24 V DC without output load.2) At 24 V DC including maximum output load.3) Freely programmable, e.g. warning field, contamination, reset required.
Mechanical data
Dimensions (W x H x D) | 102 mm x 152 mm x 106 mm |
Weight | 1.2 kg |
Housing material | Aluminum die cast |
Housing color | RAL 1021 (yellow) |
Optics cover material | Polycarbonate |
Optics cover surface finish | Outside with scratch-resistant coating |
Ambient data
Enclosure rating | IP65 (EN 60529) | ||||
Ambient operating temperature | ?10 ?C … +50 ?C | ||||
Storage temperature | ?25 ?C … +50 ?C | ||||
Vibration resistance | 5 g, 10 Hz … 150 Hz (IEC 61496, IEC 61496-3) | ||||
|
Other information
Type of light | Pulsed laser diode |
Wave length | 905 nm |
Detectable remission | 1.8 % … > 1,000 %, reflectors |
Laser class | 1 (21 CFR 1040.10 and 1040.11, IEC 60825-1) |
Classifications
ECl@ss 5.0 | 27272705 |
ECl@ss 5.1.4 | 27272705 |
ECl@ss 6.0 | 27272705 |
ECl@ss 6.2 | 27272705 |
ECl@ss 7.0 | 27272705 |
ECl@ss 8.0 | 27272705 |
ECl@ss 8.1 | 27272705 |
ECl@ss 9.0 | 27272705 |
ETIM 5.0 | EC002550 |
ETIM 6.0 | EC002550 |
UNSPSC 16.0901 | 39121528 |