UE10-3OS4D0

5,158,000

Tên sản phẩm: Safety relays UE10-3OS

Danh mục: Product portfolio

Model: UE10-3OS4D0

ID: 1028303

Nhà sản xuất: SICK

Xuất xứ: HU

Hàng mới 100%, bảo hành 12 tháng theo quy định nhà sản xuất

Cung cấp chứng nhận xuất xứ (CO), chứng nhận chất lượng (CQ) theo yêu cầu khách hàng

Mã: 1028303 Danh mục:

Mô tả sản phẩm

Product portfolio

Safety-related parameters
Safety integrity level

SIL3 (IEC 61508) 1)

SILCL3 (EN 62061) 1)

Category Category 4 (EN ISO 13849) 1)
Performance level PL e (EN ISO 13849) 1)
B10d parameter

1.26 x 106 switching cycles (AC-15, 230 V, I = 1.5 A)

5.9 x 106 switching cycles (AC-15, 230 V, I = 0.75 A)

4.35 x 105 switching cycles (DC-13, 24 V, I = 2.5 A)

1 x 107 switching cycles (DC-13, 24 V, I = 0.63 A)

PFHD (mean probability of a dangerous failure per hour) 3.0 x 10-8 (EN ISO 13849)
TM (mission time) 20 years (EN ISO 13849)
    1) If the feedback current path Y1 – Y2 (external device monitoring) is monitored using an appropriate main unit.
Interfaces
Connection type Plug-in spring terminals
Number of enable current (N/O) contacts 3, relevant for safety
Electrical data – Operating data
Voltage supply B1-B2/B3-B4
Output circuit > 25 V AC / 60 V DC PELV
Output circuit ? 25 V AC / 60 V DC PELV or SELV
Power consumption 2.4 W (DC)
Overvoltage category III (see operating instructions)
Rated insulation voltage Ui 300 V AC
Rated impulse withstand voltage Uimp 4 kV
Test voltage 2 kV (50 Hz) (EN 60439-1)
Electrical data – Input circuits: B1-B2/B3-B4
Input voltage 24 V DC (15 V DC … 30 V DC)
Input current ? 500 mA
Electrical data – Electrical output circuits: 13/14, 23/24, 33/34, 41/42, Y1/Y2
Response time (? 20 ms) 1)
Number of enable current (N/O) contacts 3, relevant for safety
Number of signalling current (N/C) contacts 1, not safety-relevant
Number of contactor monitoring (N/C) contacts 1, external device monitoring (EDM)
Contact type Positively driven
Contact material Silver alloy, gold flashed
Switching voltage
Enable current contact 10 V AC … 230 V AC
10 V DC … 300 V DC
Signalling current contact 10 V AC, 10 V DC … 230 V AC, 300 V DC
Contactor monitoring contact 10 V DC … 24 V DC
Current-carrying capacity per OSSD
Enable current contact 5 mA … 6 A
Signalling current contact 5 mA … 6 A
Contactor monitoring contact 5 mA … 100 mA
Total current ? 12 A
Usage category AC-15/DC-13 (EN 60947-5-1)
Rated operating current (voltage)

4 A (230 V AC) 360 switching cycles/h

3 A (230 V AC) 3600 switching cycles/h

4 A (24 V DC) 360 switching cycles/h

2.5 A (24 V DC) 3600 switching cycles/h

Mechanical life (relay contacts) 1 x 107 switching cycles
Electrical life (relay contacts) 2 x 106 switching cycles
    1) K1/K2.
Mechanical data
Dimensions (W x H x D) 22.5 mm x 114 mm x 96.5 mm
Weight 0.2 kg
Classifications
ECl@ss 5.0 27371990
ECl@ss 5.1.4 27371990
ECl@ss 6.0 27371819
ECl@ss 6.2 27371819
ECl@ss 7.0 27371819
ECl@ss 8.0 27371819
ECl@ss 8.1 27371819
ECl@ss 9.0 27371819
ETIM 5.0 EC001449
ETIM 6.0 EC001449
UNSPSC 16.0901 41113704