Mô tả sản phẩm
Product characteristics |
Output function |
normally open / normally closed; (selectable) |
Sensing range [mm] |
5…40; (programming buttons) |
Housing |
threaded type |
Dimensions [mm] |
M30 x 1.5 / L = 90 |
Application |
Installation |
detection through non-metallic container wall or on bypass pipes |
Media |
dry bulk material; liquids |
Electrical data |
Frequency AC [Hz] |
47…63 |
Operating voltage [V] |
30…250 AC / 20…250 DC |
Protection class |
II |
Reverse polarity protection |
yes |
Outputs |
Output function |
normally open / normally closed; (selectable) |
Max. voltage drop switching output DC [V] |
8 |
Max. voltage drop switching output AC [V] |
10 |
Max. leakage current [mA] |
2.5 (250 V AC) / 1.7 (110 V AC) / 1.5 (24 V DC) |
Permanent current rating of switching output AC [mA] |
100; (150 (…40 ?C)) |
Permanent current rating of switching output DC [mA] |
100; (150 (…40 ?C)) |
Short-time current rating of switching output [mA] |
1000; (20 ms / 0,5 Hz) |
Switching frequency AC [Hz] |
10 |
Switching frequency DC [Hz] |
10 |
Short-circuit proof |
no |
Overload protection |
no |
Detection zone |
Sensing range [mm] |
5…40; (programming buttons) |
Sensing range adjustable |
yes |
Factory setting sensing range [mm] |
20 |
Real sensing range Sr [mm] |
20 ? 10 % |
Accuracy / deviations |
Correction factor |
glass: 0.3 / water: 1 / ceramics: 0.2 / PVC: 0.1 |
Hysteresis [% of Sr] |
1…15 |
Switch point drift [% of Sr] |
-20…20 |
Operating conditions |
Ambient temperature [?C] |
-25…80 |
Note on ambient temperature |
temperature of the sensing face: -25…110 ?C |
|
Protection |
IP 65; IP 67 |
Tests / approvals |
EMC |
|
MTTF [years] |
321 |
Mechanical data |
Weight [g] |
109.8 |
Housing |
threaded type |
Mounting |
non-flush mountable |
Dimensions [mm] |
M30 x 1.5 / L = 90 |
Thread designation |
M30 x 1.5 |
Materials |
housing: PBT; plug: PC; pushbuttons: TPE-U |
Displays / operating elements |
Display |
switching status |
1 x LED ring, yellow plug lights translucently |
|
Teach function |
yes |
Electronic lock |
yes |
Electrical connection |
Required protection |
miniature fuse to IEC60127-2 sheet 1; ? 2 A; fast acting |
Accessories |
Accessories (supplied) |
|
Remarks |
Remarks |
Note: |
Check the safe functioning of the unit after a short circuit. |
|
Pack quantity |
1 pcs. |
Electrical connection – plug |
|
Connector: 1 x 1/2″ |