Mô tả sản phẩm
Product characteristics |
Output function |
normally closed |
Sensing range [mm] |
20 |
Housing |
threaded type |
Dimensions [mm] |
M30 x 1.5 / L = 81 |
Electrical data |
Operating voltage [V] |
20…250 AC/DC |
Current consumption [mA] |
< 20 |
Protection class |
II |
Reverse polarity protection |
no |
Outputs |
Output function |
normally closed |
Max. voltage drop switching output DC [V] |
8 |
Max. voltage drop switching output AC [V] |
10 |
Minimum load current [mA] |
5 |
Max. leakage current [mA] |
2.5 (250 V AC) / 1.7 (110 V AC) / 1.5 (24 V DC) |
Permanent current rating of switching output AC [mA] |
200; (350 (…50 ?C)) |
Permanent current rating of switching output DC [mA] |
200; (350 (…50 ?C)) |
Short-time current rating of switching output [mA] |
2200; (20 ms / 0,5 Hz) |
Switching frequency AC [Hz] |
10 |
Switching frequency DC [Hz] |
10 |
Short-circuit proof |
no |
Overload protection |
no |
Output holding time |
adjustable (0…60 s ) |
Detection zone |
Sensing range [mm] |
20 |
Sensing range adjustable |
yes |
Factory setting sensing range [mm] |
20 |
Real sensing range Sr [mm] |
20 ? 10 % |
Accuracy / deviations |
Hysteresis [% of Sr] |
1…15 |
Switch point drift [% of Sr] |
-20…20 |
Operating conditions |
Ambient temperature [?C] |
-25…80 |
Note on ambient temperature |
temperature of the sensing face: -25…110 |
|
Protection |
IP 65; IP 67 |
Tests / approvals |
EMC |
EN 61000-4-2 ESD |
25 kV CD / 30 kV AD |
EN 61000-4-3 HF radiated |
10 V/m |
EN 61000-4-4 Burst |
2 kV |
EN 61000-4-5 Surge |
0,5 kV line to line, Ri: 2 Ohm |
EN 61000-4-6 HF conducted |
3 V |
EN 55011 |
class B |
|
Vibration resistance |
|
(10…55 Hz) / 1 mm amplitude, oscillation period 5 min., 30 min. per axis at resonance or 55 Hz |
|
Shock resistance |
|
30 g 6 shocks / 11 ms half-sine (x, y, z) |
|
MTTF [years] |
221.4 |
Mechanical data |
Weight [g] |
186.5 |
Housing |
threaded type |
Mounting |
non-flush mountable |
Dimensions [mm] |
M30 x 1.5 / L = 81 |
Thread designation |
M30 x 1.5 |
Materials |
PBT |
Displays / operating elements |
Display |
switching status |
1 x LED, yellow |
|
Electrical connection |
Required protection |
miniature fuse to IEC60127-2 sheet 1; ? 2 A; fast acting |
Accessories |
Accessories (supplied) |
lock nuts: 2 |
screwdriver: 1 |
|
Remarks |
Remarks |
Recommendation: Check the safe functioning of the unit after a short circuit. |
|
Pack quantity |
1 pcs. |
Electrical connection |
Connection |
Cable: 2 m, PVC; 2 x 0.5 mm? |