Mô tả sản phẩm
Product characteristics |
Number of inputs and outputs |
Number of digital outputs: 2 |
Factory setting |
automatic media detection |
Probe length L [mm] |
728 |
Application |
Special feature |
Gold-plated contacts |
Media |
hydrous coolants; oils; oil-based media; water; media similar to water |
Dielectric constant of the medium |
> 2 |
Cannot be used for |
extremely conductive media; adhering media; granulates; bulk material; acids; alkali; food and electroplating industry |
Tank pressure [bar] |
0.5; (when mounting with mounting accessories: E43001 – E43007, E43019) |
Coolants |
Medium temperature [?C] |
0…35; (with climatic tube E43102) |
Oil |
Medium temperature [?C] |
0…70 |
Medium temperature short time [?C] |
0…90; (< 1 h) |
Water |
Medium temperature [?C] |
0…35; (with climatic tube E43102 35…55 ?C) |
Electrical data |
Operating voltage [V] |
12…30 DC |
Current consumption [mA] |
< 50 |
Protection class |
III |
Reverse polarity protection |
yes |
Power-on delay time [s] |
< 3 |
Inputs / outputs |
Number of inputs and outputs |
Number of digital outputs: 2 |
Outputs |
Total number of outputs |
2 |
Output signal |
switching signal; IO-Link |
Electrical design |
PNP/NPN |
Number of digital outputs |
2 |
Output function |
normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V] |
2.5 |
Permanent current rating of switching output DC [mA] |
200 |
Short-circuit protection |
yes |
Type of short-circuit protection |
thermal, pulsed |
Overload protection |
yes |
Measuring/setting range |
Factory setting |
automatic media detection |
Probe length L [mm] |
728 |
Active range A [mm] |
585 |
Inactive range I1 / I2 [mm] |
104 / 39 |
Setting range |
Set point SP [mm] |
60…590 |
Reset point rP [mm] |
50…580 |
In steps of [mm] |
10 |
Reference point OP [mm] |
200 – 240 – 280 – 310 – 350 – 390 – 420 – 460 – 500 – 530 – 570 – 610 – OFF |
Hysteresis, OP [mm] |
4 |
Accuracy / deviations |
Measuring error [% of the final value] |
? 5 |
Repeatability |
? 2 |
Resolution [mm] |
5 |
Software / programming |
Parameter setting options |
hysteresis / window; normally open / normally closed; switching logic; SP/rP position; adjustment OP; medium selection; offset setting; switch-on/switch-off delay |
Interfaces |
Communication interface |
IO-Link |
Transmission type |
COM2 (38,4 kBaud) |
IO-Link revision |
1.1 |
SDCI standard |
IEC 61131-9 |
IO-Link device ID |
0x000291 |
Profiles |
Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
SIO mode |
yes |
Required master port type |
A |
Process data analogue |
2 |
Process data binary |
2 |
Min. process cycle time [ms] |
3.2 |
Operating conditions |
Ambient temperature [?C] |
0…60 |
Storage temperature [?C] |
-25…80 |
Protection |
IP 67 |
Tests / approvals |
EMC |
DIN EN 61000-6-4 |
|
DIN EN 61000-6-2 |
|
|
Shock resistance |
DIN EN 60068-2-29 |
15 g (11 ms) |
|
Vibration resistance |
DIN EN 60068-2-6 |
5 g (10…2000 Hz) |
|
MTTF [years] |
265 |
Mechanical data |
Weight [g] |
701.8 |
Dimensions [mm] |
? 16 |
Materials |
stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); FKM; NBR; PBT; PC; PA; PP; TPV |
Materials (wetted parts) |
PP |
Displays / operating elements |
Display |
display unit / status |
2 x LED, green (cm, inch) |
switching status |
2 x LED, yellow |
measured values |
alphanumeric display, 4-digit |
parameter setting |
alphanumeric display, 4-digit |
|
Remarks |
Notes |
Please see the technical note under “Downloads” |
Pack quantity |
1 pcs. |
Electrical connection |
Connection |
Connector: 1 x M12; Contacts: gold-plated |