Mô tả sản phẩm
Product characteristics |
Number of inputs and outputs |
Number of digital outputs: 1; Number of analogue outputs: 1 |
Probe length L [mm] |
100…2000 |
Process connection |
3/4″ NPT |
Application |
Special feature |
Gold-plated contacts |
Media |
Liquids |
Dielectric constant of the medium |
> 5 |
Recommended media |
water; hydrous media |
Medium temperature [?C] |
-25…80; (90: < 1 h) |
Tank pressure [bar] |
-1…16 |
Electrical data |
Operating voltage [V] |
18…30 DC |
Current consumption [mA] |
< 25 |
Protection class |
III |
Reverse polarity protection |
yes |
Power-on delay time [s] |
< 3 |
Inputs / outputs |
Number of inputs and outputs |
Number of digital outputs: 1; Number of analogue outputs: 1 |
Outputs |
Total number of outputs |
2 |
Output signal |
switching signal; analogue signal; IO-Link |
Electrical design |
PNP/NPN |
Number of digital outputs |
1 |
Output function |
normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V] |
2.5 |
Permanent current rating of switching output DC [mA] |
200 |
Number of analogue outputs |
1 |
Analogue current output [mA] |
4…20, invertible |
Max. load [?] |
500 |
Analogue voltage output [V] |
0…10, invertible |
Min. load resistance [?] |
2000 |
Short-circuit protection |
yes |
Type of short-circuit protection |
pulsed |
Overload protection |
yes |
Measuring/setting range |
Probe length L [mm] |
100…2000 |
Active range A [mm] |
L-40 |
Inactive range I1 / I2 [mm] |
30 / 10 |
Sampling rate [Hz] |
4 |
Setting range |
Set point SP [mm] |
? 15…L-30 |
Reset point rP [mm] |
? 10…L-35 |
In steps of [mm] |
5 |
Hysteresis [mm] |
> 5 |
Accuracy / deviations |
Repeatability [mm] |
5 |
Measuring error [% of the measured value] |
? 7 mm |
Offset error [mm] |
5 |
Resolution [mm] |
1 |
Zero signal (voltage) [V] |
0 |
Zero signal (current) [mA] |
4.0 |
Full signal (voltage) [V] |
10 |
Full signal (current) [mA] |
20 |
Temperature drift per 10 K |
? 0.2 % |
Interfaces |
Communication interface |
IO-Link |
Transmission type |
COM2 (38,4 kBaud) |
IO-Link revision |
1.1 |
SDCI standard |
IEC 61131-9 |
IO-Link device ID |
592 d / 00 02 50 h |
Profiles |
Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
SIO mode |
yes |
Required master port type |
A |
Process data analogue |
3 |
Process data binary |
1 |
Min. process cycle time [ms] |
3.2 |
Operating conditions |
Ambient temperature [?C] |
-25…60 |
Storage temperature [?C] |
-40…85 |
Protection |
IP 68; IP 69K; (IP68: 7 days / 1 m water depth / 0.1 bar) |
Tests / approvals |
EMC |
DIN EN 61000-6-2 |
|
DIN EN 61000-6-3 |
: in a closed metal tank |
DIN EN 61000-6-4 |
: in plastic or open metal tanks |
|
Shock resistance |
DIN EN 60068-2-27 |
50 g (11 ms) / 25 g (6 ms) with reference rod 0.5 m |
|
Vibration resistance |
DIN EN 60068-2-6 |
5 g (10…2000 Hz) / 1 g (5…200 Hz) with reference rod 0.5 m |
|
MTTF [years] |
241 |
Mechanical data |
Weight [g] |
448.2 |
Materials |
stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); FKM; PEI |
Materials (wetted parts) |
stainless steel (1.4305 / 303); probe connection: stainless steel (1.4435 / 316L); PTFE; FKM |
Process connection |
3/4″ NPT |
Remarks |
Pack quantity |
1 pcs. |
Electrical connection – plug |
Connection |
Connector: 1 x M12; Contacts: gold-plated |
Diagrams and graphs |
|
|
Measurement deviation D at the limits of the active rod range |
|