Mô tả sản phẩm
Product portfolio
Performance
Number of steps per revolution | 512 (any number of steps from 00002 to 32768 possible. Always 5 characters in cleartext.) |
Number of revolutions | 1 |
Resolution | 512 (1) |
Error limits G | 0.035?, 0.046? (binary number of steps, non-binary number of steps) 1) |
Repeatability standard deviation ?r | 0.005? 2) |
- 1) In accordance with DIN ISO 1319-1, position of the upper and lower error limit depends on the installation situation, specified value refers to a symmetrical position, i.e. deviation in upper and lower direction is the same.2) In accordance with DIN ISO 55350-13, 68.3% of the measured values are inside the specified area.
Interfaces
Communication interface | SSI | ||||
Initialization time | 80 ms 1) | ||||
|
- 1) Valid positional data can be read once this time has elapsed.
Electrical data
Connection type | Cable, 11-wire, axial, 1.5 m |
Supply voltage range | 10 V DC … 32 V DC |
MTTFd: mean time to dangerous failure | 300 years (EN ISO 13849-1) 1) |
- 1) This product is a standard product and does not constitute a safety component as defined in the Machinery Directive. Calculation based on nominal load of components, average ambient temperature 40?C, frequency of use 8760 h/a. All electronic failures are considered hazardous. For more information, see document no. 8015532.
Mechanical data
Mechanical design | Solid shaft, face mount flange |
Shaft diameter | 10 mm x 18 mm |
Shaft length | 18 mm |
Start up torque | 0.4 Ncm |
Operating torque | 0.3 Ncm |
Permissible Load capacity of shaft |
20 N / radial 10 N / axial |
Moment of inertia of the rotor | 54 gcm? |
Bearing lifetime | 3.6 x 10^9 revolutions |
Angular acceleration | ? 500,000 rad/s? |
Ambient data
EMC | According to EN 61000-6-2 and EN 61000-6-3 1) |
Enclosure rating | IP66 (according to IEC 60529) |
Permissible relative humidity | 90 % (condensation of the optical scanning not permitted) |
Operating temperature range | ?20 ?C … +85 ?C |
Storage temperature range | ?40 ?C … +100 ?C |
Resistance to shocks | 50 g, 11 ms (according to EN 60068-2-27) |
Resistance to vibration | 20 g, 10 Hz … 2,000 Hz (according to EN 60068-2-6) |
- 1) EMC according to the standards quoted is achieved if shielded cables are used.
Classifications
ECl@ss 5.0 | 27270502 |
ECl@ss 5.1.4 | 27270502 |
ECl@ss 6.0 | 27270590 |
ECl@ss 6.2 | 27270590 |
ECl@ss 7.0 | 27270502 |
ECl@ss 8.0 | 27270502 |
ECl@ss 8.1 | 27270502 |
ECl@ss 9.0 | 27270502 |
ETIM 5.0 | EC001486 |
ETIM 6.0 | EC001486 |
UNSPSC 16.0901 | 41112113 |