Mô tả sản phẩm
Product characteristics |
Output function |
normally open / normally closed; (selectable) |
Sensing range [mm] |
60 |
Housing |
rectangular |
Dimensions [mm] |
105 x 80 x 42 |
Electrical data |
Operating voltage [V] |
20…250 AC/DC |
Protection class |
II |
Reverse polarity protection |
no |
Outputs |
Output function |
normally open / normally closed; (selectable) |
Max. voltage drop switching output DC [V] |
8 |
Max. voltage drop switching output AC [V] |
10 |
Minimum load current [mA] |
5 |
Max. leakage current [mA] |
2.5 (250 V AC) / 1.7 (110 V AC) / 1.3 (24 V DC) |
Permanent current rating of switching output AC [mA] |
130; (250 (…40 ?C)) |
Permanent current rating of switching output DC [mA] |
130; (250 (…40 ?C)) |
Short-time current rating of switching output [mA] |
1500; (20 ms / 0,5 Hz) |
Switching frequency AC [Hz] |
4 |
Switching frequency DC [Hz] |
4 |
Notes on switching frequency |
only for resistive loads; 2 Hz for utilisation category AC-140 |
|
Short-circuit proof |
no |
Overload protection |
no |
Detection zone |
Sensing range [mm] |
60 |
Sensing range adjustable |
yes |
Factory setting sensing range [mm] |
60 |
Real sensing range Sr [mm] |
60 ? 10 % |
Accuracy / deviations |
Correction factor |
glass: 0.4 / water: 1 / ceramics: 0.2 / PVC: 0.2 |
Hysteresis [% of Sr] |
1…15 |
Switch point drift [% of Sr] |
-15…15 |
Operating conditions |
Ambient temperature [?C] |
-20…60 |
Protection |
IP 65 |
Increased immunity |
yes |
Tests / approvals |
ATEX marking |
II 3D Ex tc IIIC T90?C Dc X IP65 |
EMC |
|
MTTF [years] |
270 |
Mechanical data |
Weight [g] |
281.5 |
Housing |
rectangular |
Mounting |
non-flush mountable |
Dimensions [mm] |
105 x 80 x 42 |
Materials |
PPE modified; PA |
Tightening torque [Nm] |
housing screws: 0,9 Nm; screws: 4 Nm |
Displays / operating elements |
Display |
switching status |
1 x LED, yellow |
|
Electrical connection |
Required protection |
miniature fuse to IEC60127-2 sheet 1; ? 2 A; fast acting; Place the fuse outside the hazardous area. |
Remarks |
Remarks |
Recommendation: Check the safe functioning of the unit after a short circuit. |
|
Pack quantity |
1 pcs. |
Electrical connection |
Connection |
terminals: 0.34…2.5 mm?; Cable sheath: ? 5…9 mm; Cable gland: M20 X 1.5 |