Product characteristics |
Number of inputs and outputs |
Number of digital outputs: 4 |
Probe length L [mm] |
100…1600 |
Process connection |
G 3/4 external thread |
Application |
Special feature |
Gold-plated contacts |
Media |
Liquids |
Dielectric constant of the medium |
? 1,8; (for media with a dielectric constant of 1.8…5 (e.g. oils), a coaxial pipe is needed for operation) |
Recommended media |
water; hydrous media; oils; oil-based media |
Cannot be used for |
See the operating instructions, chapter “Function and features”. |
Medium temperature [?C] |
-25…80; (90 < 1 h) |
Tank pressure [bar] |
-1…16 |
MAWP (for applications according to CRN) [bar] |
25 |
Electrical data |
Operating voltage [V] |
18…30 DC |
Current consumption [mA] |
< 80 |
Protection class |
III |
Reverse polarity protection |
yes |
Power-on delay time [s] |
< 3 |
Inputs / outputs |
Number of inputs and outputs |
Number of digital outputs: 4 |
Outputs |
Total number of outputs |
4 |
Output signal |
switching signal; IO-Link |
Electrical design |
PNP |
Number of digital outputs |
4 |
Output function |
normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V] |
2.5 |
Permanent current rating of switching output DC [mA] |
200 |
Short-circuit protection |
yes |
Type of short-circuit protection |
thermal, pulsed |
Measuring/setting range |
Probe length L [mm] |
100…1600 |
Active range A [mm] |
L-40; (when set to oil and oil based media: L-60) |
Inactive range I1 / I2 [mm] |
30 / 10; (when set to oil and oil based media: 30 / 30) |
Sampling rate [Hz] |
4 |
Setting range |
Set point SP [mm] |
? 15 / ? L-30 |
Note on setpoint SP |
when set to oil and oil based media: 35…L-30 |
|
Reset point rP [mm] |
? 10 / ? L-35 |
Note on reset point rP |
when set to oil and oil based media |
|
In steps of [mm] |
5 |
Hysteresis [mm] |
> 5 |
Accuracy / deviations |
Repeatability [mm] |
? 5 |
Measuring error [mm] |
? 7 |
Offset error [mm] |
5 |
Resolution [mm] |
1 |
Interfaces |
Communication interface |
IO-Link |
Transmission type |
COM2 (38,4 kBaud) |
IO-Link revision |
1.1 |
SDCI standard |
IEC 61131-9 CDV |
IO-Link device ID |
010 d / 00 00 0A h |
Profiles |
no profile |
SIO mode |
yes |
Required master port type |
A |
Process data analogue |
1 |
Process data binary |
4 |
Min. process cycle time [ms] |
2.3 |
Operating conditions |
Ambient temperature [?C] |
-25…60 |
Storage temperature [?C] |
-40…85 |
Protection |
IP 67 |
Tests / approvals |
EMC |
|
Shock resistance |
DIN IEC 68-2-27 |
50 g (11 ms) |
|
Vibration resistance |
DIN IEC 68-2-6 |
5 g (10…2000 Hz) |
|
MTTF [years] |
205 |
Mechanical data |
Weight [g] |
396.5 |
Materials |
stainless steel (1.4301 / 304); FKM; PBT; PC; PEI; TPE-V; PTFE |
Materials (wetted parts) |
stainless steel (1.4305 / 303); probe connection: stainless steel (1.4435 / 316L); PTFE; FKM; Sealing: NBR-PPTA 20 |
Process connection |
G 3/4 external thread |
Displays / operating elements |
Display |
Display unit |
3 x LED, green |
switching status |
4 x LED, yellow |
level |
alphanumeric display, 4-digit |
parameter setting |
alphanumeric display, 4-digit |
|
Accessories |
Accessories (optional) |
Probe:, E43203…E43205 / E43207…E43210 |
Coaxial pipe:, E43211…E43221, E43223, E43224 |
|
Remarks |
Notes |
For 8-pole sockets the core colours are not standardised.; Please note the wiring of the sensor and the sockets (see data sheet). |
Pack quantity |
1 pcs. |
Electrical connection |
Connection |
Connector: 1 x M12; Contacts: gold-plated |
Diagrams and graphs |
|
|
Measurement deviation D at the limits of the active rod range |
|