Mô tả sản phẩm
Product characteristics |
Number of inputs and outputs |
Number of digital outputs: 1; Number of analogue outputs: 1 |
Probe length L [mm] |
150…2000 |
Process connection |
G 3/4 external thread |
Application |
Special feature |
Gold-plated contacts |
Media |
Liquids; oil-based media; hydrous media |
Dielectric constant of the medium |
? 1,8; (for media with a dielectric constant of 1.8…5 (e.g. oils), a coaxial pipe is needed for operation) |
Recommended media |
water; hydrous media; oils; oil-based media |
Medium temperature [?C] |
-20…100 |
Tank pressure [bar] |
-1…16 |
Electrical data |
Operating voltage [V] |
18…30 DC |
Current consumption [mA] |
< 50 |
Protection class |
III |
Reverse polarity protection |
yes |
Power-on delay time [s] |
< 3 |
Inputs / outputs |
Number of inputs and outputs |
Number of digital outputs: 1; Number of analogue outputs: 1 |
Outputs |
Total number of outputs |
2 |
Output signal |
switching signal; analogue signal; IO-Link |
Electrical design |
PNP/NPN |
Number of digital outputs |
1 |
Output function |
normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V] |
2.5 |
Permanent current rating of switching output DC [mA] |
150; (200 (…60 ?C)) |
Number of analogue outputs |
1 |
Analogue current output [mA] |
4…20, invertible; (scalable) |
Short-circuit protection |
yes |
Type of short-circuit protection |
pulsed |
Overload protection |
yes |
Measuring/setting range |
Probe length L [mm] |
150…2000 |
Active range A [mm] |
L-40 (L-60); (when set to oil and oil based media) |
Inactive range I1 / I2 [mm] |
30 / 10 (30); (when set to oil and oil based media) |
Sampling rate [Hz] |
4 |
Setting range |
Set point SP [mm] |
? 15 (35) / ? L-30 |
Note on setpoint SP |
when set to oil and oil based media |
|
Reset point rP [mm] |
? 10 (30) / ? L-35 |
Note on reset point rP |
when set to oil and oil based media |
|
In steps of [mm] |
1 |
Hysteresis [mm] |
> 5 |
Accuracy / deviations |
Measuring error [% of the measured value] |
? 7 mm |
Offset error [mm] |
5 |
Resolution [mm] |
1 |
Zero signal (current) [mA] |
4.0 |
Full signal (current) [mA] |
20 |
Temperature drift per 10 K |
? 0.2 % |
Interfaces |
Communication interface |
IO-Link |
Transmission type |
COM2 (38,4 kBaud) |
IO-Link revision |
1.1 |
SDCI standard |
IEC 61131-9 |
IO-Link device ID |
0x000284 |
Profiles |
Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
SIO mode |
yes |
Required master port type |
A |
Process data analogue |
1 |
Process data binary |
2 |
Min. process cycle time [ms] |
2.3 |
Operating conditions |
Ambient temperature [?C] |
-40…80 |
Storage temperature [?C] |
-40…100 |
Protection |
IP 68; IP 69K |
Tests / approvals |
EMC |
DIN EN 61000-6-2 |
|
DIN EN 61000-6-3 |
: in a metal tank |
DIN EN 61000-6-4 |
: in a plastic tank |
|
Shock resistance |
DIN EN 60068-2-27 |
50 g (11 ms) / 20 g (6 ms) with reference rod 0.5 m |
|
Vibration resistance |
DIN EN 60068-2-6 |
20 g (10…2000 Hz) / 1 g (5…200 Hz) with reference rod 0.5 m |
|
MTTF [years] |
216 |
Mechanical data |
Weight [g] |
438 |
Materials |
stainless steel (1.4404 / 316L); PEI; PFA; PBT; FKM |
Materials (wetted parts) |
stainless steel (1.4404 / 316L); stainless steel (1.4435 / 316L); PTFE; FKM |
Process connection |
G 3/4 external thread |
Displays / operating elements |
Display |
Display unit |
3 x LED, green |
switching status |
2 x LED, yellow |
level |
alphanumeric display, 4-digit |
parameter setting |
alphanumeric display, 4-digit |
|
Remarks |
Pack quantity |
1 pcs. |
Electrical connection |
Connection |
Connector: 1 x M12; Contacts: gold-plated |
Diagrams and graphs |
Measurement deviation D at the limits of the active rod range |
|