Automation light grids
Features
Technology | Sender/receiver |
Minimum detectable object (MDO) | 20 mm 1) |
Beam separation | 30 mm |
Number of beams | 8 |
Detection height | 210 mm |
Evaluation beams | Cross beam |
- 1) Cross beam.
Performance
Maximum range | 3 m |
Minimum range | ? 0 mm |
Operating range | 2 m |
Response time | 84 ms 1) |
- 1) With resistive load.
Interfaces
Switching output | 2 x NPN 1) |
- 1) Q / ?.
Mechanics/electronics
Wave length | 880 nm |
Supply voltage Vs | DC 15 V … 30 V 1) |
Power consumption sender | < 100 mA 2) |
Power consumption receiver | < 100 mA 2) |
Ripple | < 5 Vpp |
Output current Imax. | ? 100 mA |
Output load capacitive | 100 nF |
Output load inductive | 1 H |
Initialization time | 1 s |
Dimensions (W x H x D) | 34 mm x 286 mm x 29 mm |
Connection type | Male connector M12, 4-pin |
Housing material | Aluminum |
Indication | LED |
Synchronization | Optical |
Enclosure rating | IP65 3) |
Circuit protection | UV connections, reverse polarity protected, Output Q short-circuit protected, Interference pulse suppression |
Protection class | III |
Weight | 1,000 g |
Pulse frequency | 250 kHz |
Front screen | PMMA |
Output mode | Q dark switching 4) |
- 1) Typical value.2) , Typical value.3) Operating in outdoor condition only with a external protection housing.4) Q = active, if at least one beam is interrupted, /Q = active, if all of the beams are free.
Ambient data
Protection class | III |
EMC | EN 60947-5-2 |
Ambient operating temperature | ?25 ?C +55 ?C |
Ambient storage temperature | ?40 ?C +70 ?C |
Ambient light immunity | Indirect: ? 150,000 lx 1) |
Vibration resistance | 5 g, 10 Hz … 55 Hz (IEC 68-2-6) |
Shock load | 10 g / DIN EN 60068-2-29 / 16 ms |
- 1) Sunlight.
Classifications
ECl@ss 5.0 | 27270910 |
ECl@ss 5.1.4 | 27270910 |
ECl@ss 6.0 | 27270910 |
ECl@ss 6.2 | 27270910 |
ECl@ss 7.0 | 27270910 |
ECl@ss 8.0 | 27270910 |
ECl@ss 8.1 | 27270910 |
ECl@ss 9.0 | 27270910 |
ETIM 5.0 | EC002549 |
ETIM 6.0 | EC002549 |
UNSPSC 16.0901 | 39121528 |