Mô tả sản phẩm
Product portfolio
Features
Module | I/O module |
Configuration method | Via software (Flexi Soft Designer, Safe EFI-pro System: Safety Designer) |
Safety-related parameters
Safety integrity level |
SIL3 (IEC 61508) SILCL3 (EN 62061) |
Category | Category 4 (EN ISO 13849) |
Performance level | PL e (EN ISO 13849) |
PFHD (mean probability of a dangerous failure per hour) | 0.4 x 10-9 (EN ISO 13849) |
TM (mission time) | 20 years (EN ISO 13849) |
Functions
Safe SICK device communication | EFI |
Flexi Loop-compatible | ? |
Interfaces
Number of safety inputs | 8 |
Number of test outputs | 8 |
Connection type | Spring terminals |
Electrical data
Protection class | III (EN 61140) | ||||||||||||
Voltage supply | Via FLEXBUS+ | ||||||||||||
Internal power consumption | ? 2 W 1) | ||||||||||||
|
|||||||||||||
|
- 1) Via FLEXBUS+, without streams at test outputs.2) On each of the two test pulse generators. This makes max. 8 testable safe series connections possible per module, each with max. 30 mA.
Mechanical data
Dimensions (W x H x D) | 22.5 mm x 96.5 mm x 120.6 mm |
Weight | 139 g (? 5 %) |
Ambient data
Enclosure rating | IP20 (EN 60529) |
Ambient operating temperature | ?25 ?C … +55 ?C |
Storage temperature | ?25 ?C … +70 ?C |
Air humidity | 10 % … 95 %, Non-condensing |
Classifications
ECl@ss 5.0 | 27242290 |
ECl@ss 5.1.4 | 27249090 |
ECl@ss 6.0 | 27249090 |
ECl@ss 6.2 | 27249090 |
ECl@ss 7.0 | 27249090 |
ECl@ss 8.0 | 27249090 |
ECl@ss 8.1 | 27249090 |
ECl@ss 9.0 | 27249090 |
ETIM 5.0 | EC002632 |
ETIM 6.0 | EC002632 |
UNSPSC 16.0901 | 32151705 |