Mô tả sản phẩm
Photoelectric sensors
Features
Sensor/ detection principle | Photoelectric retro-reflective sensor, Dual lens |
Dimensions (W x H x D) | 7.7 mm x 21.8 mm x 13.5 mm |
Housing design (light emission) | Rectangular |
Sensing range max. | 0.02 m … 3 m 1) |
Sensing range | 0.03 m … 2.5 m 1) |
Type of light | Visible red light |
Light source | PinPoint LED 2) |
Light spot size (distance) | ? 11 mm (250 mm) |
Wave length | 640 nm |
Adjustment | None |
- 1) Reflector PL40A.2) Average service life: 100,000 h at TU = +25 ?C.
Mechanics/electronics
Supply voltage | 10 V DC … 30 V DC 1) |
Ripple | ? 5 Vpp 2) |
Power consumption | 20 mA 3) |
Switching output | PNP |
Switching mode | Dark switching |
Output current Imax. | < 50 mA |
Response time | < 0.6 ms 4) |
Switching frequency | 800 Hz 5) |
Connection type | Cable with connector M8, 3-pin, 200 mm 6) |
Cable material | PVC |
Cable diameter | ? 3 mm |
Circuit protection |
A 7) C 8) D 9) |
Polarisation filter | ? |
Housing material | Plastic, ABS |
Optics material | Plastic, PMMA |
Enclosure rating | IP67 |
Ambient operating temperature | ?25 ?C … +50 ?C |
Ambient storage temperature | ?40 ?C … +75 ?C |
UL File No. | NRKH.E181493 |
- 1) Limit values when operated in short-circuit protected network: max. 8 A.2) May not exceed or fall below Uv tolerances.3) Without load.4) Signal transit time with resistive load.5) With light/dark ratio 1:1.6) Do not bend below 0 ?C.7) A = VS connections reverse-polarity protected.8) C = interference suppression.9) D = outputs overcurrent and short-circuit protected.
Classifications
ECl@ss 5.0 | 27270902 |
ECl@ss 5.1.4 | 27270902 |
ECl@ss 6.0 | 27270902 |
ECl@ss 6.2 | 27270902 |
ECl@ss 7.0 | 27270902 |
ECl@ss 8.0 | 27270902 |
ECl@ss 8.1 | 27270902 |
ECl@ss 9.0 | 27270902 |
ETIM 5.0 | EC002717 |
ETIM 6.0 | EC002717 |
UNSPSC 16.0901 | 39121528 |