GRL18-N1131V

3,355,000

Tên sản phẩm: Cylindrical photoelectric sensors GR18 Inox

Danh mục: Photoelectric sensors

Model: GRL18-N1131V

ID: 1085965

Nhà sản xuất: SICK

Xuất xứ:

Hàng mới 100%, bảo hành 12 tháng theo quy định nhà sản xuất

Cung cấp chứng nhận xuất xứ (CO), chứng nhận chất lượng (CQ) theo yêu cầu khách hàng

Mã: 1085965 Danh mục:

Mô tả sản phẩm

Photoelectric sensors

Features
Sensor/ detection principle Photoelectric retro-reflective sensor, Dual lens
Housing design (light emission) Cylindrical
Housing length 73.5 mm
Thread length 49.3 mm
Thread diameter (housing) M18 x 1
Optical axis Axial
Sensing range max. 0.03 m … 7.2 m 1)
Sensing range 0.06 m … 6 m 1)
Type of light Visible red light
Light source PinPoint LED 2)
Light spot size (distance) ? 175 mm (7 m)
Wave length 650 nm
Adjustment None
Special applications Hygienic and washdown zones
    1) Reflector PL80A.2) Average service life: 100,000 h at TU = +25 ?C.
Mechanics/electronics
Supply voltage 10 V DC … 30 V DC 1)
Ripple ? 5 Vpp 2)
Power consumption 30 mA
Switching output NPN
Output function Complementary
Switching mode Light/dark switching 3)
Signal voltage NPN HIGH/LOW Approx. VS / ? 3 V
Output current Imax. 100 mA 4)
Response time < 500 ?s 5)
Switching frequency ? 1,000 Hz 6)
Connection type Cable, 4-wire, 2 m 7)
Cable material PVC
Conductor cross-section 0.14 mm?
Cable diameter 4.8 mm
Circuit protection

A 8)

B 9)

D 10)

Protection class III
Weight 175 g
Polarisation filter ?
Housing material Stainless steel, Stainless steel V4A (1.4404, 316L)
Optics material Plastic, PMMA
Tightening torque, max. 90 Nm
Enclosure rating

IP67

IP68 11)

IP69K 12)

Items supplied Fastening nuts (2 x)
EMC EN 60947-5-2
Ambient operating temperature ?25 ?C … +55 ?C 13)
Ambient storage temperature ?30 ?C … +75 ?C
UL File No. E348498
    1) Limit values. Operated in short-circuit protected network: max. 8 A.2) May not exceed or fall below Uv tolerances.3) Q = light switching, ? = dark switching.4) At Uv > 24 V or ambient temperature > 49 ?C, IA max. = 50 mA.5) Signal transit time with resistive load.6) With light/dark ratio 1:1.7) Do not bend below 0 ?C.8) A = VS connections reverse-polarity protected.9) B = inputs and output reverse-polarity protected.10) D = outputs overcurrent and short-circuit protected.11) According to EN 60529 (10 m water depth / 24 h).12) According to ISO 20653:2013-03.13) At Uv <=24V and IA<50mA.
Classifications
ECl@ss 5.0 27270902
ECl@ss 5.1.4 27270902
ECl@ss 6.0 27270902
ECl@ss 6.2 27270902
ECl@ss 7.0 27270902
ECl@ss 8.0 27270902
ECl@ss 8.1 27270902
ECl@ss 9.0 27270902
ETIM 5.0 EC002717
ETIM 6.0 EC002717
UNSPSC 16.0901 39121528