GRSE18-N1121V

5,592,000

Tên sản phẩm: Cylindrical photoelectric sensors GR18 Inox

Danh mục: Photoelectric sensors

Model: GRSE18-N1121V

ID: 1085939

Nhà sản xuất: SICK

Xuất xứ:

Hàng mới 100%, bảo hành 12 tháng theo quy định nhà sản xuất

Cung cấp chứng nhận xuất xứ (CO), chứng nhận chất lượng (CQ) theo yêu cầu khách hàng

Mã: 1085939 Danh mục:

Mô tả sản phẩm

Photoelectric sensors

Features
Sensor/ detection principle Through-beam photoelectric sensor
Housing design (light emission) Cylindrical
Housing length 73.5 mm
Thread length 49.3 mm
Thread diameter (housing) M18 x 1
Optical axis Axial
Sensing range max. 0 m … 15 m
Sensing range 0 m … 10 m
Type of light Infrared light
Light source LED 1)
Light spot size (distance) ? 420 mm (10 m)
Wave length 850 nm
Adjustment None
Special applications Hygienic and washdown zones
    1) Average service life: 100,000 h at TU = +25 ?C.
Mechanics/electronics
Supply voltage 10 V DC … 30 V DC 1)
Ripple ? 5 Vpp 2)
Power consumption 30 mA
Switching output NPN
Output function Complementary
Switching mode Light/dark switching 3)
Signal voltage NPN HIGH/LOW Approx. VS / ? 3 V
Output current Imax. 100 mA 4)
Response time < 500 ?s 5)
Switching frequency ? 1,000 Hz 6)
Connection type Cable, 4-wire, 2 m 7)
Cable material PVC
Conductor cross-section 0.14 mm?
Cable diameter 4.8 mm
Circuit protection

A 8)

B 9)

D 10)

Protection class III
Weight 190 g
Housing material Stainless steel, Stainless steel V4A (1.4404, 316L)
Optics material Plastic, PMMA
Tightening torque, max. 90 Nm
Enclosure rating

IP67

IP68 11)

IP69K 12)

Items supplied Fastening nuts (4 x)
EMC EN 60947-5-2
Test input Sender OFF at “Test” 0 V
Ambient operating temperature ?25 ?C … +55 ?C 13)
Ambient storage temperature ?30 ?C … +75 ?C
UL File No. E348498
Part number of individual components 2091363 GRS18-D1121V 2091615 GRE18-N1111V
    1) Limit values. Operated in short-circuit protected network: max. 8 A.2) May not exceed or fall below Uv tolerances.3) Q = light switching, ? = dark switching.4) At Uv > 24 V or ambient temperature > 49 ?C, IA max. = 50 mA.5) Signal transit time with resistive load.6) With light/dark ratio 1:1.7) Do not bend below 0 ?C.8) A = VS connections reverse-polarity protected.9) B = inputs and output reverse-polarity protected.10) D = outputs overcurrent and short-circuit protected.11) According to EN 60529 (10 m water depth / 24 h).12) According to ISO 20653:2013-03.13) At Uv <=24V and IA<50mA.
Classifications
ECl@ss 5.0 27270901
ECl@ss 5.1.4 27270901
ECl@ss 6.0 27270901
ECl@ss 6.2 27270901
ECl@ss 7.0 27270901
ECl@ss 8.0 27270901
ECl@ss 8.1 27270901
ECl@ss 9.0 27270901
ETIM 5.0 EC002716
ETIM 6.0 EC002716
UNSPSC 16.0901 39121528