Mô tả sản phẩm
Safety switches
Features
Number of positive action N/C contacts | 2 |
Number of N/O contacts | 1 |
Actuation frequency | ? 6,000 /h |
Actuation torque | ? 0.14 Nm |
Actuation directions | 4 |
Approach speed | 0.1 m/min … 15 m/min |
Positive break angle | 47? |
Safety-related parameters
B10d parameter | 2 x 106 switching cycles (with small load) |
Type | Type 1 (EN ISO 14119) |
Actuator coding level | Uncoded (EN ISO 14119) |
Safe state in the event of a fault | The switch has no internal fault detection and is unable to assume a safe state in the event of a fault. Fault detection is performed by the connected safety-related logic unit. |
Functions
Safe series connection | No |
Interfaces
|
Electrical data
Switching principle | Slow action switching element |
Usage category | AC-15/DC-13 (IEC 60947-5-1) |
Rated operating current (voltage) |
3 A (240 V AC) 3 A (24 V DC) |
Rated insulation voltage Ui | 250 V |
Rated impulse withstand voltage Uimp | 2,500 V AC |
Short-circuit protection | F15 |
Switching voltage | ? 5 V DC |
Switching current (switching voltage) | ? 5 mA (5 V DC) |
Mechanical data
Weight | 0.11 kg |
Housing material | Glass-fiber reinforced thermoplastic |
Mechanical life | 10 x 106 switching cycles |
Ambient data
Enclosure rating | IP66 (IEC 60529) |
Ambient operating temperature | ?25 ?C … +80 ?C |
Storage temperature | ?25 ?C … +80 ?C |
Classifications
ECl@ss 5.0 | 27272601 |
ECl@ss 5.1.4 | 27272601 |
ECl@ss 6.0 | 27272601 |
ECl@ss 6.2 | 27272601 |
ECl@ss 7.0 | 27272601 |
ECl@ss 8.0 | 27272601 |
ECl@ss 8.1 | 27272601 |
ECl@ss 9.0 | 27272601 |
ETIM 5.0 | EC001829 |
ETIM 6.0 | EC001829 |
UNSPSC 16.0901 | 39122205 |