Mô tả sản phẩm
Safety switches
Features
Number of positive action N/C contacts | 2 |
Number of N/O contacts | 0 |
Retaining force | ? 12 N |
Actuation frequency | ? 7,200 /h |
Actuation directions | 5 |
Approach speed | ? 10 m/min |
Safety-related parameters
B10d parameter | 2 x 106 switching cycles (with small load) |
Type | Type 2 (EN ISO 14119) |
Actuator coding level | Low coding level (EN ISO 14119) |
Safe state in the event of a fault | The switch has no internal fault detection and is unable to assume a safe state in the event of a fault. Fault detection is performed by the connected safety-related logic unit. |
Functions
Safe series connection | With Flexi Loop (with diagnostics) |
Interfaces
Connection type | Plug connector, M12, 4-pin |
Electrical data
Switching principle | Slow action switching element |
Usage category | DC-13 (IEC 60947-5-1) |
Rated operating current (voltage) | 2 A (24 V DC) |
Rated insulation voltage Ui | 32 V |
Rated impulse withstand voltage Uimp | 1,500 V |
Short-circuit protection | 2 A |
Switching voltage | ? 5 V DC |
Switching current (switching voltage) | ? 5 mA (5 V DC) |
Mechanical data
Weight | + 0.54 kg |
Housing material | Zinc diecast |
Surface treatment | Varnished |
Mechanical life | 1 x 106 switching cycles |
Ambient data
Enclosure rating | IP67 (IEC 60529) |
Ambient operating temperature | ?20 ?C … +80 ?C |
Storage temperature | ?20 ?C … +80 ?C |
Classifications
ECl@ss 5.0 | 27272602 |
ECl@ss 5.1.4 | 27272602 |
ECl@ss 6.0 | 27272602 |
ECl@ss 6.2 | 27272602 |
ECl@ss 7.0 | 27272602 |
ECl@ss 8.0 | 27272602 |
ECl@ss 8.1 | 27272602 |
ECl@ss 9.0 | 27272602 |
ETIM 5.0 | EC002592 |
ETIM 6.0 | EC002592 |
UNSPSC 16.0901 | 39122205 |