Mô tả sản phẩm
Safety switches
Features
Sensor principle | Inductive |
Number of safe outputs | 2 |
Enable zone | 0.5 mm … 4 mm 1) |
Safe switch off distance Sar | 6 mm |
Actuation directions | 5 |
Active sensor surfaces | 1 |
- 1) Values apply for steel (FE360).
Safety-related parameters
Safety integrity level | SIL2 (IEC 61508), SILCL2 (EN 62061) |
Category | Applicable up to category 3 (EN ISO 13849) |
Performance level | PL d (EN ISO 13849) |
PFHD (mean probability of a dangerous failure per hour) | 1.0 x 10-7 (EN ISO 13849) |
TM (mission time) |
10 years (EN ISO 13849) 1) 20 years (EN ISO 13849) 2) |
Type | Type 3 (EN ISO 14119) |
Actuator coding level | Uncoded (EN ISO 14119) |
- 1) At ?25 ?C … +70 ?C and 5 % … 95 % relative air humidity.2) At +10 ?C … +40 ?C and 5 % … 70 % relative air humidity.
Functions
Safe series connection | With Flexi Loop (with diagnostics) |
Interfaces
Connection type | Plug connector, M12, 4-pin |
Power indication | ? |
Status display | ? |
Electrical data
Protection class | III (EN 50178) |
Supply voltage Vs | 24 V DC (19.2 V DC … 28.8 V DC) |
Type of output | Semiconductor |
Response time | ? 1 ms |
Mechanical data
Design | Cylindrical |
Housing diameter | M12 |
Weight | 0.08 kg |
Housing material | V4A (housing), PBT (cover) |
Installation type | Non-flush |
Ambient data
Enclosure rating | IP65, IP67 (IEC 60529) |
Ambient operating temperature | ?25 ?C … +70 ?C |
Storage temperature | ?25 ?C … +70 ?C |
Classifications
ECl@ss 5.0 | 27272401 |
ECl@ss 5.1.4 | 27272401 |
ECl@ss 6.0 | 27272401 |
ECl@ss 6.2 | 27272401 |
ECl@ss 7.0 | 27272401 |
ECl@ss 8.0 | 27272401 |
ECl@ss 8.1 | 27272401 |
ECl@ss 9.0 | 27272401 |
ETIM 5.0 | EC001818 |
ETIM 6.0 | EC001818 |
UNSPSC 16.0901 | 39122205 |