Mô tả sản phẩm
Product portfolio
Safety-related parameters
MTTFd: mean time to dangerous failure | 22 years (EN ISO 13849) 1) |
- 1) This product is a standard product and does not constitute a safety component as defined in the Machinery Directive. Calculation based on nominal load of components, average ambient temperature 40?C, frequency of use 8760 h/a. All electronic failures are considered hazardous. For more information, see document no. 8015532.
Performance
Measuring length | 0 m … 548 m |
Measuring range | 548 m |
Resolution | 0.1 mm |
Traversing speed | 6.6 m/s 1) |
Repeatability | 1 mm |
Measurement accuracy | ? 2000 + ME (Tu-25? C) Tk ?m 2) |
- 1) If the max. traversing speed is exceeded or if the measuring elements are left, the corresponding error message is triggered (with SSI: FF FF FE hex).2) If a positional tolerance of ? 1 mm is observed relative to the nominal distance in the N and Y directions within a measuring element relative to the starting point of this element ME = length of measuring element Tu = ambient temperature in ?C. Tk = coefficient of thermal expansion (see ?Mechanical data? table).
Interfaces
Communication interface | SSI |
Position forming time | + 0.8 ms |
Interface, digital serial | SSI, 24 Bit, gray |
Interface for parametrization |
RS-422 Default OFF Four wire transmission, asynchrony, full duplex Data format: 1 start bit, 8 data bits, 1 stop bit, no parity Data protocol: ASCII, Baud rate 9600 RS-422 |
Electrical data
Initialization time | 2 s |
Supply voltage | 10 V … 32 V |
Power consumption | 250 mA |
Connection type | Cable, 12-wire, 5 m |
MTTFd: mean time to dangerous failure | 22 years (EN ISO 13849) 1) |
- 1) This product is a standard product and does not constitute a safety component as defined in the Machinery Directive. Calculation based on nominal load of components, average ambient temperature 40?C, frequency of use 8760 h/a. All electronic failures are considered hazardous. For more information, see document no. 8015532.
Mechanical data
Weight | 6.7 kg |
Length of measuring element | See calculation example |
Position tolerance | ? 20 mm, see positional tolerances diagram |
Read head material | AlMgSiPbF28 |
Ambient data
EMC | According to EN 61000-6-2 and EN 61000-6-4 1) |
Enclosure rating | IP66 (IEC 60529) |
Operating temperature range | ?30 ?C … +70 ?C |
Storage temperature range | ?40 ?C … +85 ?C |
Resistance to shocks | 30 g, 10 ms (DIN EN 60 068-2-27) |
Resistance to vibration | 10 g, 20 Hz … 250 Hz (EN 60068-2-6) |
- 1) EMC according to the standards quoted is achieved if shielded cables are used.
Classifications
ECl@ss 5.0 | 27270705 |
ECl@ss 5.1.4 | 27270705 |
ECl@ss 6.0 | 27270705 |
ECl@ss 6.2 | 27270705 |
ECl@ss 7.0 | 27270705 |
ECl@ss 8.0 | 27270705 |
ECl@ss 8.1 | 27270705 |
ECl@ss 9.0 | 27270705 |
ETIM 5.0 | EC002544 |
ETIM 6.0 | EC002544 |
UNSPSC 16.0901 | 41111613 |