M2C-SB0250LA10

29,151,000

Tên sản phẩm: Multiple light beam safety devices deTem2 Core IP69K

Danh mục:

Model: M2C-SB0250LA10

ID: 1089984

Nhà sản xuất: SICK

Xuất xứ: DE

Hàng mới 100%, bảo hành 12 tháng theo quy định nhà sản xuất

Cung cấp chứng nhận xuất xứ (CO), chứng nhận chất lượng (CQ) theo yêu cầu khách hàng

Mã: 1089984 Danh mục:

Mô tả sản phẩm

Photoelectric sensors

Features
Sensor/ detection principle Photoelectric retro-reflective sensor, Dual lens
Dimensions (W x H x D) 20 mm x 50 mm x 39 mm
Housing design (light emission) Rectangular
Sensing range max.

0.15 m … 12 m 1)

0.15 m … 10 m 2)

Sensing range

0.3 m … 9.5 m 1)

0.3 m … 8 m 2)

Type of light Visible red light
Light source PinPoint LED 3)
Light spot size (distance) ? 58 mm (5 m)
Wave length 625 nm
Adjustment None
Special applications Detecting objects wrapped in film
Special features High functional reliability on foil-wrapped objects
    1) Reflector PL80A.2) Reflector P250.3) Average service life: 100,000 h at TU = +25 ?C.
Mechanics/electronics
Supply voltage 10 V DC … 30 V DC 1)
Ripple ? 5 Vpp 2)
Power consumption 20 mA
Switching output PNP
Switching mode Light/dark switching
Switching mode selector Selectable via light/dark selector
Output current Imax. ? 100 mA
Response time ? 1 ms 3)
Switching frequency 500 Hz 4)
Connection type Cable with M12 male connector, 4-pin, 300 mm 5)
Cable material PVC
Circuit protection

A 6)

B 7)

C 8)

D 9)

Protection class III
Weight 35 g
Polarisation filter ?
Housing material Plastic, ABS/PMMA
Enclosure rating IP67
EMC EN 60947-5-2
Ambient operating temperature ?30 ?C … +60 ?C
Ambient storage temperature ?40 ?C … +70 ?C
UL File No. NRKH.E348498 & NRKH7.E348498
More standards UL325 10)
    1) Limit values when operated in short-circuit protected network: max. 8 A.2) May not exceed or fall below Uv tolerances.3) Signal transit time with resistive load.4) With light/dark ratio 1:1.5) Do not bend below 0 ?C.6) A = VS connections reverse-polarity protected.7) B = inputs and output reverse-polarity protected.8) C = interference suppression.9) D = outputs overcurrent and short-circuit protected.10) Complies with the UL325 standard when used with sturdy protection hood (e.g. BEF-G10WSG, 2071960).
Classifications
ECl@ss 5.0 27270902
ECl@ss 5.1.4 27270902
ECl@ss 6.0 27270902
ECl@ss 6.2 27270902
ECl@ss 7.0 27270902
ECl@ss 8.0 27270902
ECl@ss 8.1 27270902
ECl@ss 9.0 27270902
ETIM 5.0 EC002717
ETIM 6.0 EC002717
UNSPSC 16.0901 39121528
Features
Dimension of the light path
Minimum 0.5 m … 12.5 m
Typical 0.5 m … 15.5 m
Number of beams 2
Beam separation 500 mm
Synchronization Optical synchronisation
Safety-related parameters
Type Type 4 (IEC 61496)
Safety integrity level

SIL3 (IEC 61508)

SILCL3 (IEC 62061)

Category Category 4 (ISO 13849)
Performance level PL e (ISO 13849)
PFHD (mean probability of a dangerous failure per hour) 3 * 10-9
TM (mission time) 20 years (ISO 13849)
Safe state in the event of a fault At least one OSSD is in the OFF state.
Interfaces
System connection
Connection type Flying leads, 5-pin
Cable length 15 m
Fieldbus, industrial network
Integration via Flexi Soft safety controller CANopen, DeviceNet?, EtherCAT?, EtherNet/IP?, Modbus TCP, PROFIBUS DP, PROFINET 1)
    1) For additional information on Flexi Soft -> www.sick.com/Flexi_Soft.
Electrical data
Protection class III (IEC 61140) 1)
Supply voltage VS 24 V DC (19.2 V DC … 28.8 V DC) 2)
Residual ripple ? 10 % 3)
Power consumption ? 50 mA
Power consumption ? 1.44 W (DC)
    1) SELV/PELV safety/protective extra-low voltage.2) The external voltage supply must be capable of buffering brief mains voltage failures of 20 ms as specified in EN 60204-1. Suitable power supplies are available as accessories from SICK.3) Within the limits of VS.
Mechanical data
Housing diameter 50 mm
Material
Protective housing Acrylic glass (PMMA)
End caps Stainless steel 1.4404
Compensating element (membrane) PA 6
Cable glands Stainless steel 1.4404 including silicone seal
Weight 1,860 g (? 50 g)
Ambient data
Enclosure rating

IP65 (IEC 60529)

IP66 (IEC 60529)

IP67 (IEC 60529)

IP69K (ISO 20653)

Ambient operating temperature ?30 ?C … +55 ?C
Storage temperature ?30 ?C … +70 ?C
Air humidity 15 % … 95 %, Non-condensing
Vibration resistance 5 g, 10 Hz … 55 Hz (IEC 60068-2-6)
Shock resistance 10 g, 16 ms (IEC 60068-2-27)
Other information
Wave length Near-infrared (NIR), invisible
Classifications
ECl@ss 5.0 27272703
ECl@ss 5.1.4 27272703
ECl@ss 6.0 27272703
ECl@ss 6.2 27272703
ECl@ss 7.0 27272703
ECl@ss 8.0 27272703
ECl@ss 8.1 27272703
ECl@ss 9.0 27272703
ETIM 5.0 EC001832
ETIM 6.0 EC001832
UNSPSC 16.0901 46171620
Features
Dimension of the light path
Minimum 0.5 m … 12.5 m
Typical 0.5 m … 15.5 m
Number of beams 2
Beam separation 500 mm
Response time 20 ms
Synchronization Optical synchronisation
Safety-related parameters
Type Type 4 (IEC 61496)
Safety integrity level

SIL3 (IEC 61508)

SILCL3 (IEC 62061)

Category Category 4 (ISO 13849)
Performance level PL e (ISO 13849)
PFHD (mean probability of a dangerous failure per hour) 3 * 10-9
TM (mission time) 20 years (ISO 13849)
Safe state in the event of a fault At least one OSSD is in the OFF state.
Interfaces
System connection
Connection type Flying leads, 5-pin
Cable length 15 m
Fieldbus, industrial network
Integration via Flexi Soft safety controller CANopen, DeviceNet?, EtherCAT?, EtherNet/IP?, Modbus TCP, PROFIBUS DP, PROFINET 1)
    1) For additional information on Flexi Soft -> www.sick.com/Flexi_Soft.
Electrical data
Protection class III (IEC 61140) 1)
Supply voltage VS 24 V DC (19.2 V DC … 28.8 V DC) 2)
Residual ripple ? 10 % 3)
Power consumption ? 150 mA
Power consumption ? 4.32 W (DC)
Safety outputs (OSSD)
Type of output 2 PNP semiconductors, short-circuit protected, cross-circuit monitored 4)
Switching voltage HIGH 24 V DC (VS ? 2.25 V DC … VS)
Switching voltage LOW ? 2 V DC
Switching current ? 300 mA
    1) SELV/PELV safety/protective extra-low voltage.2) The external voltage supply must be capable of buffering brief mains voltage failures of 20 ms as specified in EN 60204-1. Suitable power supplies are available as accessories from SICK.3) Within the limits of VS.4) Applies to the voltage range between ?30 V and +30 V.
Mechanical data
Housing diameter 50 mm
Material
Protective housing Acrylic glass (PMMA)
End caps Stainless steel 1.4404
Compensating element (membrane) PA 6
Cable glands Stainless steel 1.4404 including silicone seal
Weight 1,870 g (? 50 g)
Ambient data
Enclosure rating

IP65 (IEC 60529)

IP66 (IEC 60529)

IP67 (IEC 60529)

IP69K (ISO 20653)

Ambient operating temperature ?30 ?C … +55 ?C
Storage temperature ?30 ?C … +70 ?C
Air humidity 15 % … 95 %, Non-condensing
Vibration resistance 5 g, 10 Hz … 55 Hz (IEC 60068-2-6)
Shock resistance 10 g, 16 ms (IEC 60068-2-27)
Classifications
ECl@ss 5.0 27272703
ECl@ss 5.1.4 27272703
ECl@ss 6.0 27272703
ECl@ss 6.2 27272703
ECl@ss 7.0 27272703
ECl@ss 8.0 27272703
ECl@ss 8.1 27272703
ECl@ss 9.0 27272703
ETIM 5.0 EC001832
ETIM 6.0 EC001832
UNSPSC 16.0901 46171620
Features
Dimension of the light path
Minimum 0.5 m … 12.5 m
Typical 0.5 m … 15.5 m
Number of beams 3
Beam separation 400 mm
Synchronization Optical synchronisation
Safety-related parameters
Type Type 4 (IEC 61496)
Safety integrity level

SIL3 (IEC 61508)

SILCL3 (IEC 62061)

Category Category 4 (ISO 13849)
Performance level PL e (ISO 13849)
PFHD (mean probability of a dangerous failure per hour) 3 * 10-9
TM (mission time) 20 years (ISO 13849)
Safe state in the event of a fault At least one OSSD is in the OFF state.
Interfaces
System connection
Connection type Flying leads, 5-pin
Cable length 15 m
Fieldbus, industrial network
Integration via Flexi Soft safety controller CANopen, DeviceNet?, EtherCAT?, EtherNet/IP?, Modbus TCP, PROFIBUS DP, PROFINET 1)
    1) For additional information on Flexi Soft -> www.sick.com/Flexi_Soft.
Electrical data
Protection class III (IEC 61140) 1)
Supply voltage VS 24 V DC (19.2 V DC … 28.8 V DC) 2)
Residual ripple ? 10 % 3)
Power consumption ? 50 mA
Power consumption ? 1.44 W (DC)
    1) SELV/PELV safety/protective extra-low voltage.2) The external voltage supply must be capable of buffering brief mains voltage failures of 20 ms as specified in EN 60204-1. Suitable power supplies are available as accessories from SICK.3) Within the limits of VS.
Mechanical data
Housing diameter 50 mm
Material
Protective housing Acrylic glass (PMMA)
End caps Stainless steel 1.4404
Compensating element (membrane) PA 6
Cable glands Stainless steel 1.4404 including silicone seal
Weight 2,190 g (? 50 g)
Ambient data
Enclosure rating

IP65 (IEC 60529)

IP66 (IEC 60529)

IP67 (IEC 60529)

IP69K (ISO 20653)

Ambient operating temperature ?30 ?C … +55 ?C
Storage temperature ?30 ?C … +70 ?C
Air humidity 15 % … 95 %, Non-condensing
Vibration resistance 5 g, 10 Hz … 55 Hz (IEC 60068-2-6)
Shock resistance 10 g, 16 ms (IEC 60068-2-27)
Other information
Wave length Near-infrared (NIR), invisible
Classifications
ECl@ss 5.0 27272703
ECl@ss 5.1.4 27272703
ECl@ss 6.0 27272703
ECl@ss 6.2 27272703
ECl@ss 7.0 27272703
ECl@ss 8.0 27272703
ECl@ss 8.1 27272703
ECl@ss 9.0 27272703
ETIM 5.0 EC001832
ETIM 6.0 EC001832
UNSPSC 16.0901 46171620
Features
Dimension of the light path
Minimum 0.5 m … 12.5 m
Typical 0.5 m … 15.5 m
Number of beams 3
Beam separation 400 mm
Response time 20 ms
Synchronization Optical synchronisation
Safety-related parameters
Type Type 4 (IEC 61496)
Safety integrity level

SIL3 (IEC 61508)

SILCL3 (IEC 62061)

Category Category 4 (ISO 13849)
Performance level PL e (ISO 13849)
PFHD (mean probability of a dangerous failure per hour) 3 * 10-9
TM (mission time) 20 years (ISO 13849)
Safe state in the event of a fault At least one OSSD is in the OFF state.
Interfaces
System connection
Connection type Flying leads, 5-pin
Cable length 15 m
Fieldbus, industrial network
Integration via Flexi Soft safety controller CANopen, DeviceNet?, EtherCAT?, EtherNet/IP?, Modbus TCP, PROFIBUS DP, PROFINET 1)
    1) For additional information on Flexi Soft -> www.sick.com/Flexi_Soft.
Electrical data
Protection class III (IEC 61140) 1)
Supply voltage VS 24 V DC (19.2 V DC … 28.8 V DC) 2)
Residual ripple ? 10 % 3)
Power consumption ? 150 mA
Power consumption ? 4.32 W (DC)
Safety outputs (OSSD)
Type of output 2 PNP semiconductors, short-circuit protected, cross-circuit monitored 4)
Switching voltage HIGH 24 V DC (VS ? 2.25 V DC … VS)
Switching voltage LOW ? 2 V DC
Switching current ? 300 mA
    1) SELV/PELV safety/protective extra-low voltage.2) The external voltage supply must be capable of buffering brief mains voltage failures of 20 ms as specified in EN 60204-1. Suitable power supplies are available as accessories from SICK.3) Within the limits of VS.4) Applies to the voltage range between ?30 V and +30 V.
Mechanical data
Housing diameter 50 mm
Material
Protective housing Acrylic glass (PMMA)
End caps Stainless steel 1.4404
Compensating element (membrane) PA 6
Cable glands Stainless steel 1.4404 including silicone seal
Weight 2,200 g (? 50 g)
Ambient data
Enclosure rating

IP65 (IEC 60529)

IP66 (IEC 60529)

IP67 (IEC 60529)

IP69K (ISO 20653)

Ambient operating temperature ?30 ?C … +55 ?C
Storage temperature ?30 ?C … +70 ?C
Air humidity 15 % … 95 %, Non-condensing
Vibration resistance 5 g, 10 Hz … 55 Hz (IEC 60068-2-6)
Shock resistance 10 g, 16 ms (IEC 60068-2-27)
Classifications
ECl@ss 5.0 27272703
ECl@ss 5.1.4 27272703
ECl@ss 6.0 27272703
ECl@ss 6.2 27272703
ECl@ss 7.0 27272703
ECl@ss 8.0 27272703
ECl@ss 8.1 27272703
ECl@ss 9.0 27272703
ETIM 5.0 EC001832
ETIM 6.0 EC001832
UNSPSC 16.0901 46171620
Features
Dimension of the light path
Minimum 0.5 m … 12.5 m
Typical 0.5 m … 15.5 m
Number of beams 4
Beam separation 300 mm
Synchronization Optical synchronisation
Safety-related parameters
Type Type 4 (IEC 61496)
Safety integrity level

SIL3 (IEC 61508)

SILCL3 (IEC 62061)

Category Category 4 (ISO 13849)
Performance level PL e (ISO 13849)
PFHD (mean probability of a dangerous failure per hour) 3 * 10-9
TM (mission time) 20 years (ISO 13849)
Safe state in the event of a fault At least one OSSD is in the OFF state.
Interfaces
System connection
Connection type Flying leads, 5-pin
Cable length 15 m
Fieldbus, industrial network
Integration via Flexi Soft safety controller CANopen, DeviceNet?, EtherCAT?, EtherNet/IP?, Modbus TCP, PROFIBUS DP, PROFINET 1)
    1) For additional information on Flexi Soft -> www.sick.com/Flexi_Soft.
Electrical data
Protection class III (IEC 61140) 1)
Supply voltage VS 24 V DC (19.2 V DC … 28.8 V DC) 2)
Residual ripple ? 10 % 3)
Power consumption ? 50 mA
Power consumption ? 1.44 W (DC)
    1) SELV/PELV safety/protective extra-low voltage.2) The external voltage supply must be capable of buffering brief mains voltage failures of 20 ms as specified in EN 60204-1. Suitable power supplies are available as accessories from SICK.3) Within the limits of VS.
Mechanical data
Housing diameter 50 mm
Material
Protective housing Acrylic glass (PMMA)
End caps Stainless steel 1.4404
Compensating element (membrane) PA 6
Cable glands Stainless steel 1.4404 including silicone seal
Weight 2,290 g (? 50 g)
Ambient data
Enclosure rating

IP65 (IEC 60529)

IP66 (IEC 60529)

IP67 (IEC 60529)

IP69K (ISO 20653)

Ambient operating temperature ?30 ?C … +55 ?C
Storage temperature ?30 ?C … +70 ?C
Air humidity 15 % … 95 %, Non-condensing
Vibration resistance 5 g, 10 Hz … 55 Hz (IEC 60068-2-6)
Shock resistance 10 g, 16 ms (IEC 60068-2-27)
Other information
Wave length Near-infrared (NIR), invisible
Classifications
ECl@ss 5.0 27272703
ECl@ss 5.1.4 27272703
ECl@ss 6.0 27272703
ECl@ss 6.2 27272703
ECl@ss 7.0 27272703
ECl@ss 8.0 27272703
ECl@ss 8.1 27272703
ECl@ss 9.0 27272703
ETIM 5.0 EC001832
ETIM 6.0 EC001832
UNSPSC 16.0901 46171620
Features
Dimension of the light path
Minimum 0.5 m … 12.5 m
Typical 0.5 m … 15.5 m
Number of beams 4
Beam separation 300 mm
Response time 20 ms
Synchronization Optical synchronisation
Safety-related parameters
Type Type 4 (IEC 61496)
Safety integrity level

SIL3 (IEC 61508)

SILCL3 (IEC 62061)

Category Category 4 (ISO 13849)
Performance level PL e (ISO 13849)
PFHD (mean probability of a dangerous failure per hour) 3 * 10-9
TM (mission time) 20 years (ISO 13849)
Safe state in the event of a fault At least one OSSD is in the OFF state.
Interfaces
System connection
Connection type Flying leads, 5-pin
Cable length 15 m
Fieldbus, industrial network
Integration via Flexi Soft safety controller CANopen, DeviceNet?, EtherCAT?, EtherNet/IP?, Modbus TCP, PROFIBUS DP, PROFINET 1)
    1) For additional information on Flexi Soft -> www.sick.com/Flexi_Soft.
Electrical data
Protection class III (IEC 61140) 1)
Supply voltage VS 24 V DC (19.2 V DC … 28.8 V DC) 2)
Residual ripple ? 10 % 3)
Power consumption ? 150 mA
Power consumption ? 4.32 W (DC)
Safety outputs (OSSD)
Type of output 2 PNP semiconductors, short-circuit protected, cross-circuit monitored 4)
Switching voltage HIGH 24 V DC (VS ? 2.25 V DC … VS)
Switching voltage LOW ? 2 V DC
Switching current ? 300 mA
    1) SELV/PELV safety/protective extra-low voltage.2) The external voltage supply must be capable of buffering brief mains voltage failures of 20 ms as specified in EN 60204-1. Suitable power supplies are available as accessories from SICK.3) Within the limits of VS.4) Applies to the voltage range between ?30 V and +30 V.
Mechanical data
Housing diameter 50 mm
Material
Protective housing Acrylic glass (PMMA)
End caps Stainless steel 1.4404
Compensating element (membrane) PA 6
Cable glands Stainless steel 1.4404 including silicone seal
Weight 2,300 g (? 50 g)
Ambient data
Enclosure rating

IP65 (IEC 60529)

IP66 (IEC 60529)

IP67 (IEC 60529)

IP69K (ISO 20653)

Ambient operating temperature ?30 ?C … +55 ?C
Storage temperature ?30 ?C … +70 ?C
Air humidity 15 % … 95 %, Non-condensing
Vibration resistance 5 g, 10 Hz … 55 Hz (IEC 60068-2-6)
Shock resistance 10 g, 16 ms (IEC 60068-2-27)
Classifications
ECl@ss 5.0 27272703
ECl@ss 5.1.4 27272703
ECl@ss 6.0 27272703
ECl@ss 6.2 27272703
ECl@ss 7.0 27272703
ECl@ss 8.0 27272703
ECl@ss 8.1 27272703
ECl@ss 9.0 27272703
ETIM 5.0 EC001832
ETIM 6.0 EC001832
UNSPSC 16.0901 46171620
Features
Dimension of the light path
Minimum 0.5 m … 12.5 m
Typical 0.5 m … 15.5 m
Number of beams 2
Beam separation 500 mm
Synchronization Optical synchronisation
Safety-related parameters
Type Type 2 (IEC 61496)
Safety integrity level

SIL1 (IEC 61508)

SILCL1 (IEC 62061)

Category Category 2 (ISO 13849)
Performance level PL c (ISO 13849)
PFHD (mean probability of a dangerous failure per hour) 3 * 10-9
TM (mission time) 20 years (ISO 13849)
Safe state in the event of a fault At least one OSSD is in the OFF state.
Interfaces
System connection
Connection type Flying leads, 5-pin
Cable length 15 m
Fieldbus, industrial network
Integration via Flexi Soft safety controller CANopen, DeviceNet?, EtherCAT?, EtherNet/IP?, Modbus TCP, PROFIBUS DP, PROFINET 1)
    1) For additional information on Flexi Soft -> www.sick.com/Flexi_Soft.
Electrical data
Protection class III (IEC 61140) 1)
Supply voltage VS 24 V DC (19.2 V DC … 28.8 V DC) 2)
Residual ripple ? 10 % 3)
Power consumption ? 50 mA
Power consumption ? 1.44 W (DC)
    1) SELV/PELV safety/protective extra-low voltage.2) The external voltage supply must be capable of buffering bri