MM18-00A-N-ZC0

2,106,000

Tên sản phẩm: Magnetic proximity sensors MM Namur

Danh mục: Product portfolio

Model: MM18-00A-N-ZC0

ID: 1026614

Nhà sản xuất: SICK

Xuất xứ: HU

Hàng mới 100%, bảo hành 12 tháng theo quy định nhà sản xuất

Cung cấp chứng nhận xuất xứ (CO), chứng nhận chất lượng (CQ) theo yêu cầu khách hàng

Mã: 1026614 Danh mục:

Mô tả sản phẩm

Product portfolio

Features
Housing Cylindrical thread design
Thread size M18 x 1
Diameter ? 18 mm
Sensing range Sn 5 mm … 120 mm 1)
Safe sensing range Sa 97.2 mm
Magnetic sensitivity ? 0.4 mT
Switching frequency 5,000 Hz
Connection type Male connector M12, 4-pin
Switching output NAMUR
Output characteristic Control current depending on switching state according to NAMUR EN 60947-5-6
Electrical wiring DC 2-wire
Magnetic alignment Axial
Enclosure rating IP67 2)
    1) Sensing range based on installation in non-magnetic material using Magnet MAG-3010-B (M4.0).2) According to EN 60529.
Mechanics/electronics
Ripple ? 5 % 1)
Time delay before availability ? 2 ms
Hysteresis 1 % … 10 %
Reproducibility ? 1 % 2)
Temperature drift (of Sr) ? 10 %
EMC According to EN 60947-5-2
Current consumption, sensor is activated ? 2.5 mA
Current consumption, sensor is not activated ? 1 mA
Cable resistance ? 50 ?
Wire-break protection ?
Short-circuit protection ?
Reverse polarity protection ?
Shock and vibration resistance 30 g, 11 ms / 10 … 55 Hz, 1 mm
Ambient operating temperature ?25 ?C … +70 ?C
Housing material Metal, Stainless steel V4A (1.4404, 316L)
Housing length 65 mm
Thread length 40 mm
Tightening torque, max. ? 25 Nm
Items supplied Mounting nut, V4A stainless steel (2x)
EC Approval Certificate T?V 99 ATEX 1398
ATEX marking EX II 2G Ex ib IIC T6 Gb Ta: – 25 ?C … + 70 ?C
Ex area category 2G
Input voltage Ui max. 16 V 3)
Input power Pi max. 100 mW 3)
Input current Ii max. 30 mA 3)
Internal capacitance Ci max. 15 nF 3)
Internal inductance Li max. 35 ?H 3)
Nominal voltage 8.2 V DC
Special feature Advanced sensing range
    1) Of VS.2) Von Sr (VS und Ta constant).3) For connection to a separately certified intrinsically safe circuit only.
Classifications
ECl@ss 5.0 27270104
ECl@ss 5.1.4 27270104
ECl@ss 6.0 27270104
ECl@ss 6.2 27270104
ECl@ss 7.0 27270104
ECl@ss 8.0 27270104
ECl@ss 8.1 27270104
ECl@ss 9.0 27270104
ETIM 5.0 EC002544
ETIM 6.0 EC002544
UNSPSC 16.0901 39122230