OD2-N50W10U2

26,524,000

Tên sản phẩm: Displacement measurement sensors OD Value

Danh mục: Distance sensors

Model: OD2-N50W10U2

ID: 6036585

Nhà sản xuất: SICK

Xuất xứ: JP

Hàng mới 100%, bảo hành 12 tháng theo quy định nhà sản xuất

Cung cấp chứng nhận xuất xứ (CO), chứng nhận chất lượng (CQ) theo yêu cầu khách hàng

Mã: 6036585 Danh mục:

Mô tả sản phẩm

Distance sensors

Performance
Measuring range 40 mm … 60 mm 1)
Target Natural objects
Repeatability 5 ?m 1) 2) 3)
Linearity ? 20 ?m 2) 4) 5)
Response time ? 1 ms
Measuring frequency ? 2 kHz 1)
Output time ? 0.5 ms
Light source Laser, red
Laser class 2 (IEC 60825-1:2014, EN 60825-1:2014) 6)
Typ. light spot size (distance) 0.5 mm x 1 mm (50 mm)
Additional function Mean-value setting 1 ? 64x, automatic sensitivity adjustment, Analog outputs can be taught in, Invertable analog output, Teach-in of switching output, Invertable switching output, multifunctional input: laser-off / external teach-in / trigger, switching mode: distance to object (DtO), switching mode: window (Wnd)
    1) 6 % … 90 % remission.2) At averaging function medium.3) Constant ambient conditions.4) Measurement on 90 % remission (ceramic, white).5) When calibrated in the application regularly.6) Wavelength: 655 nm, max. output: 1 mW.
Interfaces
Digital output
Number 2 1)
Type NPN
Maximum output current IA ? 100 mA
Analog output 1 x 0 V … 10 V (> 10 k?)
Resolution analog output 16 bit
Multifunctional input (MF) 1 x MF 2)
    1) PNP: HIGH = VS – (< 2 V) / LOW = < 2 V, NPN: HIGH = < 2 V / LOW = VS.2) MF can be used as laser-off, trigger, external teach-in, or deactivated, response time ? 3 ms.
Mechanics/electronics
Supply voltage Vs DC 18 V … 24 V
Power consumption ? 2.88 W 1)
Warm-up time ? 30 min
Housing material PBT
Window material PMMA
Connection type Cable, 2 m
Indication Distance bar graph, up to 8 status LEDs
Weight 70 g
Enclosure rating IP67
Protection class III
    1) Without load, with current output.
Ambient data
Ambient temperature operation ?10 ?C … +40 ?C
Ambient storage temperature ?20 ?C … +60 ?C
Relative air humidity (non-condensing) 35 % … 95 %
Temperature drift ? 0.08 % FS/K (FS = Full Scale = Measuring range of sensor)
Typ. Ambient light immunity

Artificial light: ? 3,000 lx

Sunlight: ? 10,000 lx

Vibration resistance 10 Hz … 55 Hz (amplitude 1.5 mm, x-, y-, z-axis 2 hours each)
Shock resistance 50 G (x, y, z axis 3 times each)
Classifications
ECl@ss 5.0 27270801
ECl@ss 5.1.4 27270801
ECl@ss 6.0 27270801
ECl@ss 6.2 27270801
ECl@ss 7.0 27270801
ECl@ss 8.0 27270801
ECl@ss 8.1 27270801
ECl@ss 9.0 27270801
ETIM 5.0 EC001825
ETIM 6.0 EC001825
UNSPSC 16.0901 41111613