Mô tả sản phẩm
Product portfolio
Features
Usage | Can only be used in the EFI system network, e.g., with a Flexi Soft safety controller and an additional S300 or S3000 safety laser scanner |
Protective field range | 4 m |
Warning field range | 49 m (20 m at 20 % reflectivity) |
Distance measuring range | 49 m |
Number of simultaneously monitored protective fields | ? 4 1) |
Type of field set | Triple field sets, dual field sets |
Number of field sets | 32 2) 3) |
Number of fields | 64 |
Number of monitoring cases | 32 3) |
Scanning angle | 190? |
Resolution (can be configured) | 30 mm, 40 mm, 50 mm, 70 mm, 150 mm |
Angular resolution | 0.5?, 0.25?, depending on range and resolution |
Response time | 60 ms 4) |
Protective field supplement | 100 mm |
Number of multiple samplings | 2 … 16, configurable |
Delay of automatic reset | 2 s … 60 s, configurable |
- 1) If several protective fields are monitored simultaneously, the shut-off signals must be connected to safe outputs on a Flexi Soft safety controller or routed via a safe EFI gateway.2) In dual field mode 32, in triple field mode 21 field sets.3) The performance characteristics of the Remote device correspond to those of the host. If the system exclusively consists of Remote devices connected to an EFI partner, 16 dual field sets or 10 triple field sets and 32 monitoring cases are available. For monitoring case switching static or dynamic inputs of the EFI partner have to be used.4) Depending on basic response time and multiple sampling.
Safety-related parameters
Type | Type 3 (IEC 61496) |
Safety integrity level |
SIL2 (IEC 61508) SILCL2 (EN 62061) |
Category | Category 3 (EN ISO 13849) |
Performance level | PL d (EN ISO 13849) |
PFHD (mean probability of a dangerous failure per hour) | 8.0 x 10-8 (EN ISO 13849) |
TM (mission time) | 20 years (EN ISO 13849) |
Safe state in the event of a fault | At least one OSSD is in the OFF state. |
Functions
Restart interlock | ? |
External device monitoring (EDM) | ? |
Multiple sampling | ? |
Monitoring case switching | ? |
Simultaneous monitoring | ? |
Static protective field switching | ? |
Dynamic protective field switching | ? |
Contour as a reference | ? |
Integrated configuration memory | ? |
Measured data output | ? |
Safe SICK device communication via EFI | ? |
Electrical data
Protection class | II (EN 50178) | ||||||
Supply voltage Vs | 24 V DC (16.8 V DC … 28.8 V DC) | ||||||
Power consumption |
? 0.8 A 1) ? 2.3 A 2) |
||||||
|
- 1) At 24 V DC without output load.2) At 24 V DC including maximum output load.3) Freely programmable, e.g. warning field, contamination, reset required.
Mechanical data
Dimensions (W x H x D) | 155 mm x 185 mm x 160 mm |
Weight | 3.3 kg |
Housing material | Aluminum die cast |
Housing color | RAL 1021 (yellow) |
Front screen material | Polycarbonate |
Front screen surface finish | Outside with scratch-resistant coating |
Ambient data
Enclosure rating | IP65 (EN 60529) | ||||
Ambient operating temperature | ?10 ?C … +50 ?C | ||||
Storage temperature | ?25 ?C … +50 ?C | ||||
Vibration resistance | 5 g, 10 Hz … 150 Hz (IEC 61496, IEC 61496-3) | ||||
|
Other information
Type of light | Pulsed laser diode |
Wave length | 905 nm |
Detectable remission | 1.8 % … > 1,000 %, reflectors |
Laser class | 1 (21 CFR 1040.10 and 1040.11, IEC 60825-1) |
Classifications
ECl@ss 5.0 | 27272705 |
ECl@ss 5.1.4 | 27272705 |
ECl@ss 6.0 | 27272705 |
ECl@ss 6.2 | 27272705 |
ECl@ss 7.0 | 27272705 |
ECl@ss 8.0 | 27272705 |
ECl@ss 8.1 | 27272705 |
ECl@ss 9.0 | 27272705 |
ETIM 5.0 | EC002550 |
ETIM 6.0 | EC002550 |
UNSPSC 16.0901 | 39121528 |