Mô tả sản phẩm
Features
Number of simultaneously monitored protective fields | ? 4 1) |
Angular resolution | Depending on range and resolution |
Response time | 60 ms 2) |
- 1) If several protective fields are monitored simultaneously, the shut-off signals must be connected to safe outputs on a Flexi Soft safety controller or routed via a safe EFI gateway.2) Depending on basic response time and multiple sampling.
Safety-related parameters
Type | Type 3 (IEC 61496) |
Safety integrity level |
SIL2 (IEC 61508) SILCL2 (EN 62061) |
Category | Category 3 (EN ISO 13849) |
Performance level | PL d (EN ISO 13849) |
PFHD (mean probability of a dangerous failure per hour) | 8.0 x 10-8 (EN ISO 13849) |
TM (mission time) | 20 years (EN ISO 13849) |
Functions
External device monitoring (EDM) | ? |
Integrated configuration memory | ? |
Measured data output | ? |
Safe SICK device communication via EFI | ? |
Electrical data
Protection class | II (EN 50178) | ||||||
Supply voltage Vs | 24 V DC (16.8 V DC … 28.8 V DC) | ||||||
Power consumption |
? 0.8 A 1) ? 2.3 A 2) |
||||||
|
- 1) At 24 V DC without output load.2) At 24 V DC including maximum output load.3) Freely programmable, e.g. warning field, contamination, reset required.
Ambient data
Enclosure rating | IP65 (EN 60529) | ||||
Ambient operating temperature | ?10 ?C … +50 ?C | ||||
Storage temperature | ?25 ?C … +50 ?C | ||||
Vibration resistance | 5 g, 10 Hz … 150 Hz (IEC 61496, IEC 61496-3) | ||||
|
Classifications
ECl@ss 5.0 | 27272705 |
ECl@ss 5.1.4 | 27272705 |
ECl@ss 6.0 | 27272705 |
ECl@ss 6.2 | 27272705 |
ECl@ss 7.0 | 27272705 |
ECl@ss 8.0 | 27272705 |
ECl@ss 8.1 | 27272705 |
ECl@ss 9.0 | 27272705 |
ETIM 5.0 | EC002550 |
ETIM 6.0 | EC002550 |
UNSPSC 16.0901 | 39121528 |