Mô tả sản phẩm
Opto-electronic protective devices
Features
Protective field range |
3 m |
Warning field range |
8 m (at 15 % reflectivity) |
Distance measuring range |
30 m |
Type of field set |
Triple field sets |
Number of field sets |
8 |
Number of fields |
24 |
Number of monitoring cases |
32 1) |
Scanning angle |
270? |
Resolution (can be configured) |
30 mm, 40 mm, 50 mm, 70 mm, 150 mm |
Angular resolution |
0.5? |
Response time |
80 ms 2) |
Protective field supplement |
100 mm |
Number of multiple samplings |
2 … 16, configurable |
Delay of automatic reset |
2 s … 60 s, configurable |
Safety-related parameters
Type |
Type 3 (IEC 61496) |
Safety integrity level |
SIL2 (IEC 61508)
SILCL2 (EN 62061)
|
Category |
Category 3 (EN ISO 13849) |
Performance level |
PL d (EN ISO 13849) |
PFHD (mean probability of a dangerous failure per hour) |
8.0 x 10-8 (EN ISO 13849) |
TM (mission time) |
20 years (EN ISO 13849) |
Safe state in the event of a fault |
At least one OSSD is in the OFF state. |
Functions
Restart interlock |
? |
External device monitoring (EDM) |
? |
Multiple sampling |
? |
Monitoring case switching |
? |
Static protective field switching |
? |
Dynamic protective field switching |
? |
Contour as a reference |
? |
Integrated configuration memory |
? |
Measured data output |
? |
Safe SICK device communication via EFI |
? |
Interfaces
Connection type |
System plug with or without connecting cable |
|
Universal I/Os? |
5 1) |
Inputs |
|
External device monitoring (EDM) |
1 2) |
Reset/restart |
1 2) |
Static control inputs |
3 3) |
Static control inputs with EFI |
5 4) |
Dynamic control inputs (incremental encoder) |
2 5) |
Standby |
1 |
|
Outputs |
|
OSSD pairs |
1 |
Diagnostic outputs |
3 6) |
|
Configuration method |
PC with CDS (Configuration and Diagnostic Software) |
Configuration and diagnostics interface |
RS-232 |
Transmission rate |
38.4 kBaud |
|
Data interface |
RS-422 |
Transmission rate |
? 500 kBaud |
|
Safe SICK device communication via EFI |
|
Transmission rate |
? 500 kBaud |
Length of cable |
? 50 m |
Conductor cross-section |
0.22 mm? |
|
Fieldbus, industrial network |
|
Integration via EFI gateways |
CANopen, Ethernet, PROFIBUS DP, PROFIBUS PROFIsafe, PROFINET PROFIsafe 7) |
|
Electrical data
Protection class |
III (EN 50178, EN 60950) |
Supply voltage Vs |
24 V DC (16.8 V DC … 30 V DC) |
Power consumption |
? 0.33 A 1)
? 1.7 A 2)
|
Outputs |
|
Output signal switching devices (OSSDs) |
2 x 250 mA |
Diagnostic outputs |
3 x 100 mA 3) |
|
Mechanical data
Dimensions (W x H x D) |
102 mm x 152 mm x 106 mm |
Weight |
1.2 kg |
Housing material |
Aluminum die cast |
Housing color |
RAL 1021 (yellow) |
Optics cover material |
Polycarbonate |
Optics cover surface finish |
Outside with scratch-resistant coating |
Ambient data
Enclosure rating |
IP65 (EN 60529) |
Ambient operating temperature |
?10 ?C … +50 ?C |
Storage temperature |
?25 ?C … +50 ?C |
Vibration resistance |
5 g, 10 Hz … 150 Hz (IEC 61496, IEC 61496-3) |
Shock resistance |
|
Continuous shock |
10 g, 16 ms (IEC 61496, IEC 61496-3) |
|
Other information
Type of light |
Pulsed laser diode |
Wave length |
905 nm |
Detectable remission |
1.8 % … > 1,000 %, reflectors |
Laser class |
1 (21 CFR 1040.10 and 1040.11, IEC 60825-1) |
Classifications
ECl@ss 5.0 |
27272705 |
ECl@ss 5.1.4 |
27272705 |
ECl@ss 6.0 |
27272705 |
ECl@ss 6.2 |
27272705 |
ECl@ss 7.0 |
27272705 |
ECl@ss 8.0 |
27272705 |
ECl@ss 8.1 |
27272705 |
ECl@ss 9.0 |
27272705 |
ETIM 5.0 |
EC002550 |
ETIM 6.0 |
EC002550 |
UNSPSC 16.0901 |
39121528 |