SIG100-0A0111100

5,377,000

Tên sản phẩm: Sensor Integration Gateway SIG100

Danh mục: Integration products

Model: SIG100-0A0111100

ID: 1089792

Nhà sản xuất: SICK

Xuất xứ: DE

Hàng mới 100%, bảo hành 12 tháng theo quy định nhà sản xuất

Cung cấp chứng nhận xuất xứ (CO), chứng nhận chất lượng (CQ) theo yêu cầu khách hàng

Mã: 1089792 Danh mục:

Mô tả sản phẩm

Integration products

Features
Supported products

Binary switching sensors

Binary actuators

Further functions USB connection for easy configuration of the SIG100 Sensor Integration Gateway with SOPAS ET, the engineering tool from SICK, logic editor is available for easy configuration of logic functions
Interfaces
Logic editor ?
USB ?
IO-Link ? , V1.1, Port Class A
Function IO-Link sensor hub (IO-Link slave) with 6 ports which can be used to connect sensors and actuators. the SIG100 Sensor Integration Gateway can therefore connect up to 12 binary switching signals and communicate them via IO-Link to any IO-Link master. SIG100 can also be operated as a standalone system by directly configuring simple logic functions across several connected devices via the SOPAS ET user interface.
IO-Link data transmission rate ? 38.4 kBaud, COM2
IO-Link cycle time < 5.1 ms
IO-Link process data length 8 Byte In und 2 Byte Out
IO-Link process data structure
8 Byte Process Data In Bit 0 – Bit 7 = QL1 – QL8
Bit 8 – Bit 19 = Qint1 – Qint12
Bit 20 ? bit 31 = Reserved
Bit 32 ? bit 39 = Analog value 1 (lower byte)
Bit 40 ? bit 47 = Analog value 1 (upper byte)
Bit 48 ? bit 55 = Analog value 2 (lower byte)
Bit 56 ? bit 63 = Analog value 2 (upper byte)
2 bytes process data out (digital mode) Bit 0 – Bit 15 = IL1 – IL16
2 bytes process data out (analog mode) Bit 0 ? bit 7 = Analog value in (lower byte)
Bit 8 ? bit 15 = Analog value in (upper byte)
Comment QL1 ? QL8 = Logic editor outputs
Qint1 ? Qint12 = Mapping of the individual ports (S1?S6), each with Pin2 and Pin4, onto the IO-Link process data
4 bytes analog value 1/2 = Transmission of integer values (e.g., counter value)
IL1 ? IL16 = Logic editor inputs
2 bytes analog value in = Transmission of integer values (e.g., counter value)
Operator interfaces SOPAS ET, the engineering tool for configuration via USB, SOPAS ET can be downloaded for free from www.sick.com, the required SSD file for displaying SIG100 via SOPAS ET can either be downloaded from the device or from www.sick.com
Number of inputs Max. 12 x PNP, type 1
Number of outputs Max. 12 x PNP
Inputs/outputs
S1-S6 6 ports, Pin2 and Pin4 can be customized as a digital input or digital output to enable the transmission of up to 12 digital input or output signals.
CONFIG Port for configuration via USB with SOPAS ET (SOPAS ET can be downloaded for free from www.sick.com)
Optical indicators

12 Orange (Activity displays, 2 for each port S1?S6 for the display of Pin4 (DI/DO1) and Pin2 (DI/DO2))

1 Green (Power/C display)

Mechanics/electronics
Connections
I/O 6 x M12, 5-pin female connector, A-coded
Power Main 1 x M12, 5-pin male connector, A-coded
CONFIG 1 x M8, 4-pin female connector, USB 2.0 (USB-A)
Supply voltage 10 V DC … 30 V DC 1)
Current consumption ? 70 mA without connected sensor
Output current max. ? 500 mA total, all connections
Output current
S1-S6 I/O supply current ? 50 mA
S1-S6 I/O switching outputs ? 50 mA
Power Port I/O 50 mA
Enclosure rating IP67
Protection class III
Electrical safety EN 60950-1 (2011-01)
Housing material ABS
Housing color Light blue (RAL 5012)
Weight 289 g
Dimensions (L x W x H) 198.5 mm x 57 mm x 38.3 mm
    1) 10 – 30 V DC without IO-Link, 18 – 30 V DC with IO-Link.
Ambient data
Electromagnetic compatibility (EMC)

EN 61000-6-2:2005-08

EN 61000-6-3 (2007-01)

Shock load EN 60068-2-6
Ambient operating temperature ?40 ?C … +60 ?C 1)
Ambient storage temperature ?40 ?C … +70 ?C 1)
    1) Permissible relative air humidity: 0 % … 90 % (non-condensing).
Classifications
ECl@ss 5.0 27242208
ECl@ss 5.1.4 27242608
ECl@ss 6.0 27242608
ECl@ss 6.2 27242608
ECl@ss 7.0 27242608
ECl@ss 8.0 27242608
ECl@ss 8.1 27242608
ECl@ss 9.0 27242608
ETIM 5.0 EC001604
ETIM 6.0 EC001604
UNSPSC 16.0901 32151705