Mô tả sản phẩm
Motor feedback systems
Safety-related parameters
Safety integrity level | SIL2 (IEC 61508), SILCL2 (IEC 62061) |
Category | 3 (EN ISO 13849) |
Maximum demand rate | Continuous (analog signals) |
Performance level | PL d (EN ISO 13849) 1) |
PFHD: Probability of dangerous failure per hour | 1.0 x 10-8 2) |
TM (mission time) | 20 years (EN ISO 13849) |
MTTFd: mean time to dangerous failure | 1,073 years (EN ISO 13849) |
- 1) For more detailed information on the exact configuration of your machine/unit, please consult your relevant SICK branch office.2) The values displayed apply to a diagnostic degree of coverage of 90%, which must be achieved by the external drive system.
Performance
Sine/cosine periods per revolution | 1,024 |
Number of the absolute ascertainable revolutions | 4,096 |
Total number of steps | 134,217,728 |
Measuring step | 0.3 ? For interpolation of the sine/cosine signals with, e. g., 12 bits |
Integral non-linearity | Typ. ? 45 ?, Error limits for evaluating sine/cosine period, without mechanical tension of the stator coupling |
Differential non-linearity | ? 7 ?, Non-linearity within a sine/cosine period |
Operating speed | ? 6,000 min??, up to which the absolute position can be reliably produced |
Available memory area | 128 Byte |
Interfaces
Type of code for the absolute value | Binary |
Code sequence | Increasing, when turning the shaft For clockwise rotation, looking in direction ?A? (see dimensional drawing), For clockwise shaft rotation, looking in direction ?A? (see dimensional drawing) |
Communication interface | HIPERFACE? |
Electrical data
Connection type | Male connector, 8-pin, radial |
Supply voltage range | 7 V DC … 12 V DC |
Recommended supply voltage | 8 V DC |
Output current | 80 mA 1) |
Output frequency for sine/cosine signals | ? 200 kHz |
- 1) Without load.
Mechanical data
Shaft version | Tapered shaft |
Flange type / stator coupling | Spring mounting plate, Spring mounting plate |
Dimensions | See dimensional drawing |
Weight | ? 0.2 kg |
Moment of inertia of the rotor | 10 gcm? |
Operating speed | ? 12,000 min?? |
Angular acceleration | ? 200,000 rad/s? |
Operating torque | 0.2 Ncm |
Start up torque | + 0.4 Ncm |
Permissible movement of the drive element, static |
? 0.3 mm radial ? 0.75 mm axial |
Permissible movement of the drive element, dynamic |
? 0.1 mm radial ? 0.2 mm axial |
Angular motion perpendicular to the rotational axis, static | ? 0.005 mm/mm |
Angular motion perpendicular to the rotational axis, dynamic | ? 0.0025 mm/mm |
Life of ball bearings | 3.6 x 10^9 revolutions |
Ambient data
Operating temperature range | ?30 ?C … +115 ?C |
Storage temperature range | ?40 ?C … +125 ?C, without package |
Relative humidity/condensation | 90 %, Condensation not permitted |
Resistance to shocks | 100 g, 10 ms, 10 ms (according to EN 60068-2-27) |
Frequency range of resistance to vibrations | 20 g, 10 Hz … 2,000 Hz (according to EN 60068-2-6) |
EMC | According to EN 61000-6-2 and EN 61000-6-3 1) |
Enclosure rating | IP40, with mating connector inserted (according to IEC 60529) |
- 1) The EMC according to the standards quoted is achieved when the motor feedback system is mounted in an electrically conductive housing, which is connected to the central earthing point of the motor controller via a cable screen. The GND-(0 V) connection of the supply voltage is also grounded here. If other shielding concepts are used, users must perform their own tests.
Classifications
ECl@ss 5.0 | 27270590 |
ECl@ss 5.1.4 | 27270590 |
ECl@ss 6.0 | 27270590 |
ECl@ss 6.2 | 27270590 |
ECl@ss 7.0 | 27270590 |
ECl@ss 8.0 | 27270590 |
ECl@ss 8.1 | 27270590 |
ECl@ss 9.0 | 27270590 |
ETIM 5.0 | EC001486 |
ETIM 6.0 | EC001486 |
UNSPSC 16.0901 | 41112113 |