STR1-SAMF10P8

8,205,000

Tên sản phẩm: Non-contact safety switches STR1 / Transponder safety switch / Sensor and actuator

Danh mục: Safety switches

Model: STR1-SAMF10P8

ID: 1077184

Nhà sản xuất: SICK

Xuất xứ: MY

Hàng mới 100%, bảo hành 12 tháng theo quy định nhà sản xuất

Cung cấp chứng nhận xuất xứ (CO), chứng nhận chất lượng (CQ) theo yêu cầu khách hàng

Mã: 1077184 Danh mục:

Mô tả sản phẩm

Safety switches

Features
System part Sensor and actuator
Sensor principle Transponder
Number of safe outputs 2
Auxiliary contact (AUX) 1 (Switching behavior complementary to OSSDs)
Safe switch on distance Sao
Active front sensor surface 14 mm
Active side sensor surface 9 mm
Safe switch off distance Sar 28 mm
Active sensor surfaces 3
Actuation directions 5
Coding Permanently coded
Safety-related parameters
Safety integrity level SIL3 (IEC 61508), SILCL3 (EN 62061)
Category Category 4 (EN ISO 13849)
Performance level PL e (EN ISO 13849)
PFHD (mean probability of a dangerous failure per hour) 5,21 x 10-9 (EN ISO 13849)
TM (mission time) 20 years (EN ISO 13849)
Type Type 4 (EN ISO 14119)
Actuator coding level High coding level (EN ISO 14119)
Safe state in the event of a fault At least one safety-related semiconductor output (OSSD) is in the OFF state.
Functions
Safe series connection In control cabinet (with diagnostics)
Interfaces
Connection type Cable, 7-wire
Length of cable 10 m
Cable material PVC
Diagnostics indicator ?
Status display ?
Electrical data
Protection class III (IEC 61140)
Classification according to cULus Class 2
Supply voltage Vs 24 V DC (19.2 V DC … 28.8 V DC)
Power consumption 50 mA
Type of output Semiconductor (OSSD)
Output current ? 100 mA
Response time 40 ms 1)
Enable time 100 ms 1) 2)
Risk time 80 ms 1) 3)
Switch-on time 2.5 s 4)
    1) In a safe series connection, each downstream safety switch increases the system response time. More response times can be found in the operating instructions.2) Response time on approach to the enable zone.3) Detection time for internal oder external faults (e.g., short-circuit or cross-circuit of output signal switching devices). Follow the detailed information in the operating instructions.4) The time specified applies to one sensor after the supply voltage has been applied to the safety switch. In a safe series connection, 0.1?s must be added for each sensor. An additional 0.5?s per taught-in actuator must be added for uniquely coded and permanently coded sensors.
Mechanical data
Dimensions (W x H x D) 40 mm x 18 mm x 26 mm
Weight 453 g
Housing material VISTAL?
Ambient data
Enclosure rating

IP67 (EN 60529)

IPX9K (ISO 20653)

Ambient operating temperature ?10 ?C … +70 ?C
Storage temperature ?25 ?C … +70 ?C
Vibration resistance 10 Hz … 55 Hz, 1 mm (IEC 60068-2-6)
Shock resistance 30 g, 11 ms (IEC 60068-2-27)
EMC

EN IEC 61326-3-1

EN IEC 60947-5-2

EN IEC 60947-5-3

EN 300330 V2.1.1

Classifications
ECl@ss 5.0 27272403
ECl@ss 5.1.4 27272403
ECl@ss 6.0 27272403
ECl@ss 6.2 27272403
ECl@ss 7.0 27272403
ECl@ss 8.0 27272403
ECl@ss 8.1 27272403
ECl@ss 9.0 27272403
ETIM 5.0 EC001829
ETIM 6.0 EC001829
UNSPSC 16.0901 39122205