Tên sản phẩm: Motor feedback systems linear HIPERFACE? TTK50

Danh mục: Motor feedback systems

Model: TTK50-HXM0K02

ID: 1067934

Nhà sản xuất: SICK

Xuất xứ: DE

Hàng mới 100%, bảo hành 12 tháng theo quy định nhà sản xuất

Cung cấp chứng nhận xuất xứ (CO), chứng nhận chất lượng (CQ) theo yêu cầu khách hàng

Mã: 1067934 Danh mục:

Mô tả sản phẩm

Motor feedback systems

Performance

Performance

Measuring step 0.244 ?m For interpolation of the sine/cosine signals with, e. g., 12 bits
Measuring length ? 940 mm
Length of period 1 mm
Traversing speed ? 10 m/s, 1.3 m/s, up to which the absolute position can be reliably produced
Repeatability < 5 ?m
System accuracy ? 10 ?m (+20 ?C)
Measured value backlash < 10 ?m
Interfaces

Interfaces

Electrical interface HIPERFACE?
Code type Binary
Available memory area 1,972 Byte (E2PROM 2048)
Electrical data

Electrical data

Supply voltage 7 V DC … 12 V DC
Recommended supply voltage 8 V DC
Operating current ? 55 mA (without load) 1)
Connection type Cable, 8-wire, 5 m
    1) 100 mA approx. during adjustment.
Mechanical data

Mechanical data

Dimensions See dimensional drawing
Weight 0.06 kg, without cable
Read head material Zinc diecast
Ambient data

Ambient data

EMC According to EN 61000-6-2 and EN 61000-6-3 1)
Enclosure rating IP65, with mating connector inserted (according to IEC 60529)
Operating temperature range ?30 ?C … +80 ?C
Storage temperature range ?40 ?C … +85 ?C, without package
Permissible relative humidity 100 %, condensation permitted
Resistance to shocks 30 g, 6 ms (EN 60068-2-27)
Resistance to vibration 20 g, 10 Hz … 2,000 Hz (EN 60068-2-6)
Maximum permitted ambient field strength < 3 kA/m ... 4 kA/m (3.8 mT ... 5 mT), to guarantee compliance with the quoted accuracy values 2)
Maximum permitted field strength < 150 kA/m (< 190 mT), to ensure that the magnetic tape is not permanently damaged
    1) The EMC according to the standards quoted is achieved when the motor feedback system with put-on mating connector is connected to the central earthing point of the motor controller via a cable screen and via the encoder housing extensive connected to the motor potential. Users must perform their own tests when other screening designs are used.2) The maximum permitted external field influence is reached when the position value deviates from the original value (without external field influence) by more than 5 ?m. This value is reached when, at the sensor location, a field strength of 3 kA/m to 4 kA/m (3.8 mT to 5 mT) occurs in addition to the field strength of the magnetic tape.
Classifications

Classifications

ECl@ss 5.0 27270590
ECl@ss 5.1.4 27270590
ECl@ss 6.0 27270590
ECl@ss 6.2 27270590
ECl@ss 7.0 27270590
ECl@ss 8.0 27270590
ECl@ss 8.1 27270590
ECl@ss 9.0 27270590
ETIM 5.0 EC001486
ETIM 6.0 EC001486
UNSPSC 16.0901 41112113