UE12-2FG3D0

3,709,000

Tên sản phẩm: Safety relays UE12-2FG

Danh mục: Product portfolio

Model: UE12-2FG3D0

ID: 1043918

Nhà sản xuất: SICK

Xuất xứ: DE

Hàng mới 100%, bảo hành 12 tháng theo quy định nhà sản xuất

Cung cấp chứng nhận xuất xứ (CO), chứng nhận chất lượng (CQ) theo yêu cầu khách hàng

Mã: 1043918 Danh mục:

Mô tả sản phẩm

Product portfolio

Safety-related parameters
Safety integrity level

SIL3 (IEC 61508) 1)

SILCL3 (EN 62061) 1)

Category Category 4 (EN ISO 13849) 1)
Performance level PL e (EN ISO 13849) 1)
B10d parameter

1 x 105 switching cycles (AC-15, 230 V, I = 2 A)

2.5 x 105 switching cycles (AC-15, 230 V, I = 1 A)

5.4 x 105 switching cycles (DC-13, 24 V, I = 0.5 A)

1 x 107 switching cycles (DC-13, 24 V, I ? 2 A)

PFHD (mean probability of a dangerous failure per hour) 1.2 x 10-9 (EN ISO 13849)
TM (mission time) 20 years (EN ISO 13849)
    1) If the feedback current path Y1 – Y2 (external device monitoring) is monitored using an appropriate main unit.
Interfaces
Connection type Plug-in screw-type terminals
Number of enable current (N/O) contacts 2, relevant for safety
Number of contactor monitoring (N/C) contacts 1
Electrical data – Operating data
Voltage supply B1/A2, B2/A2
Output circuit > 25 V AC / 60 V DC PELV
Output circuit ? 25 V AC / 60 V DC PELV or SELV
Residual ripple (? 2.4 Vpp) 1)
Power consumption (? 2 W (DC))
Overvoltage category II
Rated insulation voltage Ui 300 V AC
Rated impulse withstand voltage Uimp 4 kV
Test voltage 1.2 kV (50 Hz) (EN 60439-1)
    1) In DC operation, within the limits of VS.
Electrical data – Input circuits: B1, B2
Input voltage 24 V DC (16.8 V DC … 27.6 V DC)
Input current ? 50 mA
Reset time ? 30 ms
Test pulse width ? 1 ms
Electrical data – Electrical output circuits: 13/14, 23/24, Y1/Y2
Response time (? 10 ms)
Number of enable current (N/O) contacts 2, relevant for safety
Number of contactor monitoring (N/C) contacts 1, external device monitoring (EDM)
Contact type Positively driven
Contact material Silver alloy, gold flashed
Switching voltage
Enable current contact 10 V AC/DC … 250 V AC/DC
Contactor monitoring contact 0.1 V AC/DC … 60 V AC/DC
Current-carrying capacity per OSSD
Enable current contact 10 mA … 6 A
Contactor monitoring contact 1 mA … 300 mA
Switching capacity ? 1,500 VA (AC)
? 200 W (DC)
Usage category AC-15/DC-13 (EN 60947-5-1)
Rated operating current (voltage)

3 A (230 V AC)

4 A (24 V DC)

Mechanical life (relay contacts) 1 x 107 switching cycles
Electrical life (relay contacts) 1 x 105 switching cycles
Mechanical data
Dimensions (W x H x D) 17.8 mm x 105.5 mm x 70.8 mm
Weight 91 g
Classifications
ECl@ss 5.0 27371990
ECl@ss 5.1.4 27371990
ECl@ss 6.0 27371819
ECl@ss 6.2 27371819
ECl@ss 7.0 27371819
ECl@ss 8.0 27371819
ECl@ss 8.1 27371819
ECl@ss 9.0 27371819
ETIM 5.0 EC001449
ETIM 6.0 EC001449
UNSPSC 16.0901 41113704