Registration sensors
Functional principle | Optical detection principle |
Dimensions (W x H x D) | 10 mm x 88.5 mm x 74 mm |
Housing design (light emission) | Fork shaped |
Fork width | 50 mm |
Fork depth | 59 mm |
Minimum detectable object (MDO) | 0.05 mm |
Light source | Laser, visible red light |
Wave length | 670 nm |
Laser class | I |
Adjustment |
Teach-in button (Teach-in, sensitivity, light/dark switching, key lock) Cable (Teach-in dynamic) |
Teach-in mode |
1-point teach-in 2-point teach-in Teach-in dynamic |
Output function | Light/darkswitching, selectable via button |
IO-Link functions | Standard |
Advanced functions | ? 1) |
Fieldbus, industrial network | IO-Link |
Type of fieldbus integration | Integrated in the device |
- 1) On request also availible with advanced funktions A70 or A71.
Supply voltage | 10 V DC … 30 V DC 1) |
Ripple | < 10 % 2) |
Power consumption | 40 mA 3) |
Switching frequency | 11 kHz 4) |
Response time | 60 ?s 5) |
Stability of response time | ? 20 ?s |
Jitter | 22 ?s |
Switching output | PUSH/PULL |
Switching output (voltage) | Push/Pull: High = VS – < 2 V / Low: ? 2 V |
Switching output | Light/dark switching |
Output current Imax. | 100 mA |
Input, teach-in (ET) |
Teach: U > 5 V … < UV Run: U < 4 V |
Initialization time | 40 ms |
Connection type | Male connector M8, 4-pin |
Ambient light immunity | Sunlight: ? 10,000 lx |
Protection class | III 6) |
Circuit protection |
UV connections, reverse polarity protected Output Q short-circuit protected Interference pulse suppression |
Enclosure rating | IP65 |
Weight | Approx. 36 g … 160 g 7) |
Housing material | Aluminum |
- 1) Limit values, reverse-polarity protected, operation in short-circuit protected network: max. 8 A.2) May not exceed or fall below Uv tolerances.3) Without load.4) With light/dark ratio 1:1.5) Signal transit time with resistive load.6) Reference voltage DC 50 V.7) Depending on fork width.
Ambient operating temperature | ?20 ?C … +50 ?C 1) |
Ambient storage temperature | ?30 ?C … +80 ?C |
Shock load | According to EN 60068-2-27 |
- 1) Do not bend below 0 ?C.
ECl@ss 5.0 | 27270909 |
ECl@ss 5.1.4 | 27270909 |
ECl@ss 6.0 | 27270909 |
ECl@ss 6.2 | 27270909 |
ECl@ss 7.0 | 27270909 |
ECl@ss 8.0 | 27270909 |
ECl@ss 8.1 | 27270909 |
ECl@ss 9.0 | 27270909 |
ETIM 5.0 | EC002720 |
ETIM 6.0 | EC002720 |
UNSPSC 16.0901 | 39121528 |
Communication interface | IO-Link V1.1 |
Communication Interface detail | COM2 (38,4 kBaud) |
Cycle time | 2.3 ms |
Process data length | 16 Bit |
Process data structure A |
Bit 0 = switching signal QL1 Bit 1 = switching signal QL2 Bit 2 = not used Bit 3 = Teach busy Bit 4 … 15 = empty |
Process data structure B |
Bit 0 = switching signal QL1 Bit 1 = Quality of Run Alarm Bit 2 = not used Bit 3 = Teach busy Bit 4 … 15 = empty |
Process data structure C |
Bit 0 = switching signal QL1 Bit 1 = switching signal QL2 Bit 2 = not used Bit 3 = Teach busy Bit 4 … 5 = empty Bit 6 … 15 = measuring value |
Process data structure D |
Bit 0 = switching signal QL1 Bit 1 = Quality of Run Alarm Bit 2 = not used Bit 3 = Teach busy Bit 4 … 5 = empty Bit 6 … 15 = measuring value |