WL4SLG-3E1134

7,791,000

Tên sản phẩm: Miniature photoelectric sensors W4SLG-3

Danh mục: Photoelectric sensors

Model: WL4SLG-3E1134

ID: 1058248

Nhà sản xuất: SICK

Xuất xứ: DE

Hàng mới 100%, bảo hành 12 tháng theo quy định nhà sản xuất

Cung cấp chứng nhận xuất xứ (CO), chứng nhận chất lượng (CQ) theo yêu cầu khách hàng

Mã: 1058248 Danh mục:

Mô tả sản phẩm

Photoelectric sensors

Features
Sensor/ detection principle Photoelectric retro-reflective sensor, autocollimation
Dimensions (W x H x D) 12.2 mm x 41.8 mm x 17.3 mm
Housing design (light emission) Rectangular
Mounting hole M3
Sensing range max. 0 m … 4.5 m 1)
Sensing range 0 m … 2 m 1)
Type of light Visible red light
Light source Laser 2)
Light spot size (distance) ? 1 mm (500 mm)
Wave length 650 nm
Laser class 1 (EN 60825-1:2014, IEC 60825-1:2014 / CDRH 21 CFR 1040.10 & 1040.11)
Adjustment Cable, Single teach-in button 3)
AutoAdapt ?
Special applications Detecting transparent objects, Detecting small objects
    1) Reflective tape REF-AC1000.2) Average service life: 50,000 h at TU = +25 ?C.3) Adjustment via cable (ET): white cable or PIN2 according to the desired sensitivity > 2 … < 8 s or put > 8 s on L+ (PNP) or on M (NPN).
Mechanics/electronics
Supply voltage 10 V DC … 30 V DC 1)
Ripple < 5 Vpp 2)
Power consumption 30 mA 3)
Switching output NPN 4)
Switching mode Dark switching 4)
Output current Imax. ? 100 mA
Response time ? 0.5 ms 5)
Switching frequency 1,000 Hz 6)
Connection type Cable, 4-wire, 2 m 7)
Cable material PVC
Conductor cross-section 0.14 mm?
Circuit protection

A 8)

B 9)

C 10)

Protection class III
Weight 100 g
Polarisation filter ?
Housing material Plastic, Novodur
Optics material Plastic, PMMA
Enclosure rating

IP66

IP67

Special feature Detecting transparent objects
Ambient operating temperature ?10 ?C … +50 ?C
Ambient operating temperature extended ?30 ?C … +55 ?C 11) 12)
Ambient storage temperature ?30 ?C … +70 ?C
    1) Limit values when operated in short-circuit protected network: max. 8 A.2) May not exceed or fall below Uv tolerances.3) Without load.4) Q = dark switching.5) Signal transit time with resistive load.6) With light/dark ratio 1:1.7) Do not bend below 0 ?C.8) A = VS connections reverse-polarity protected.9) B = inputs and output reverse-polarity protected.10) C = interference suppression.11) As of Ta = 50 ?C, a max. supply voltage Vmax. = 24 V and a max. load current Imax. = 50 mA is permitted.12) Operation below Tu ?10 ?C is possible if the sensor is already switched on at Tu > ?10 ?C, then cools down, and the supply voltage is subsequently not switched off. Switching on below Tu ?10 ?C is not permissible.
Classifications
ECl@ss 5.0 27270902
ECl@ss 5.1.4 27270902
ECl@ss 6.0 27270902
ECl@ss 6.2 27270902
ECl@ss 7.0 27270902
ECl@ss 8.0 27270902
ECl@ss 8.1 27270902
ECl@ss 9.0 27270902
ETIM 5.0 EC002717
ETIM 6.0 EC002717
UNSPSC 16.0901 39121528