Mô tả sản phẩm
Photoelectric sensors
Features
Sensor/ detection principle | Photoelectric retro-reflective sensor, autocollimation |
Dimensions (W x H x D) | 12.2 mm x 41.8 mm x 17.3 mm |
Housing design (light emission) | Rectangular |
Mounting hole | M3 |
Sensing range max. | 0 m … 4.5 m 1) |
Sensing range | 0 m … 2 m 1) |
Type of light | Visible red light |
Light source | Laser 2) |
Light spot size (distance) | ? 1 mm (500 mm) |
Wave length | 650 nm |
Laser class | 1 (EN 60825-1:2014, IEC 60825-1:2014 / CDRH 21 CFR 1040.10 & 1040.11) |
Adjustment | Single teach-in button |
AutoAdapt | ? |
Special applications | Detecting transparent objects, Detecting small objects |
- 1) Reflective tape REF-AC1000.2) Average service life: 50,000 h at TU = +25 ?C.
Mechanics/electronics
Supply voltage | 10 V DC … 30 V DC 1) |
Ripple | < 5 Vpp 2) |
Power consumption | 30 mA 3) |
Switching output | PNP |
Switching mode | Light switching |
Output current Imax. | ? 100 mA |
Response time | ? 0.5 ms 4) |
Switching frequency | 1,000 Hz 5) |
Connection type | Cable with connector M8, 3-pin, 100 mm 6) |
Cable material | PVC |
Conductor cross-section | 0.14 mm? |
Circuit protection |
A 7) B 8) C 9) |
Protection class | III |
Weight | 100 g |
Polarisation filter | ? |
Housing material | Plastic, Novodur |
Optics material | Plastic, PMMA |
Enclosure rating |
IP66 IP67 |
Special feature | Detecting transparent objects |
Ambient operating temperature | ?10 ?C … +50 ?C |
Ambient operating temperature extended | ?30 ?C … +55 ?C 10) 11) |
Ambient storage temperature | ?30 ?C … +70 ?C |
MTTFd: mean time to dangerous failure | 647 years (EN ISO 13849-1) 12) |
- 1) Limit values when operated in short-circuit protected network: max. 8 A.2) May not exceed or fall below Uv tolerances.3) Without load.4) Signal transit time with resistive load.5) With light/dark ratio 1:1.6) Do not bend below 0 ?C.7) A = VS connections reverse-polarity protected.8) B = inputs and output reverse-polarity protected.9) C = interference suppression.10) As of Ta = 50 ?C, a max. supply voltage Vmax. = 24 V and a max. load current Imax. = 50 mA is permitted.11) Operation below Tu ?10 ?C is possible if the sensor is already switched on at Tu > ?10 ?C, then cools down, and the supply voltage is subsequently not switched off. Switching on below Tu ?10 ?C is not permissible.12) Mode of calculation: Parts-Count-calculation.
Classifications
ECl@ss 5.0 | 27270902 |
ECl@ss 5.1.4 | 27270902 |
ECl@ss 6.0 | 27270902 |
ECl@ss 6.2 | 27270902 |
ECl@ss 7.0 | 27270902 |
ECl@ss 8.0 | 27270902 |
ECl@ss 8.1 | 27270902 |
ECl@ss 9.0 | 27270902 |
ETIM 5.0 | EC002717 |
ETIM 6.0 | EC002717 |
UNSPSC 16.0901 | 39121528 |