Mô tả sản phẩm
Photoelectric sensors
Features
Sensor/ detection principle | Photoelectric retro-reflective sensor, autocollimation |
Dimensions (W x H x D) | 12.2 mm x 52.2 mm x 23.6 mm |
Housing design (light emission) | Rectangular |
Mounting hole | M3 |
Sensing range max. | 0 m … 3.5 m 1) |
Sensing range | 0 m … 2.2 m 1) |
Type of light | Visible red light |
Light source | Laser 2) |
Light spot size (distance) | ? 0.4 mm (60 mm) |
Wave length | 650 nm |
Laser class | 1 (IEC 60825-1 / CDRH 21 CFR 1040.10 & 1040.11) |
Adjustment |
IO-Link Single teach-in button |
Pin 2 configuration | External input, Teach-in input, Sender off input, Detection output, logic output, alarm output quality of run |
Diagnosis | Quality of run, Quality of teach-in |
AutoAdapt | ? |
Special applications | Detecting small objects, Detecting transparent objects |
- 1) Reflective tape REF-AC1000.2) Average service life: 50,000 h at TU = +25 ?C.
Mechanics/electronics
Supply voltage | 10 V DC … 30 V DC 1) |
Ripple | < 5 Vpp 2) |
Power consumption | 30 mA 3) |
Switching output | PNP 4) |
Output function | Complementary |
Switching mode | Light/dark switching 4) |
Output current Imax. | ? 100 mA |
Response time | ? 0.5 ms 5) |
Response time Q/ on Pin 2 | 300 ?s … 450 ?s 5) 6) |
Switching frequency | 1,000 Hz 7) |
Switching frequency Q / to pin 2 | ? 1,000 Hz 8) |
Connection type | Male connector M12, 4-pin |
Circuit protection |
A 9) B 10) C 11) |
Protection class | III |
Weight | 13 g |
Polarisation filter | ? |
IO-Link | ? |
Housing material | Plastic, VISTAL? |
Optics material | Plastic, PMMA |
Enclosure rating |
IP66 IP67 IP69K |
Special feature | Detecting transparent objects |
Ambient operating temperature | ?10 ?C … +50 ?C |
Ambient operating temperature extended | ?30 ?C … +55 ?C 12) 13) |
Ambient storage temperature | ?30 ?C … +70 ?C |
UL File No. | NRKH.E181493 |
Repeatability Q/ on Pin 2: | 150 ?s 6) |
- 1) Limit values when operated in short-circuit protected network: max. 8 A.2) May not exceed or fall below Uv tolerances.3) Without load.4) Q = light switching.5) Signal transit time with resistive load.6) Valid for Q on Pin2, if configured with software.7) With light/dark ratio 1:1.8) With light / dark ratio 1:1, valid for Q on Pin2, if configured with software.9) A = VS connections reverse-polarity protected.10) B = inputs and output reverse-polarity protected.11) C = interference suppression.12) As of Ta = 50 ?C, a max. supply voltage Vmax. = 24 V and a max. load current Imax. = 50 mA is permitted.13) Operation below Tu ?10 ?C is possible if the sensor is already switched on at Tu > ?10 ?C, then cools down, and the supply voltage is subsequently not switched off. Switching on below Tu ?10 ?C is not permissible.
Classifications
ECl@ss 5.0 | 27270902 |
ECl@ss 5.1.4 | 27270902 |
ECl@ss 6.0 | 27270902 |
ECl@ss 6.2 | 27270902 |
ECl@ss 7.0 | 27270902 |
ECl@ss 8.0 | 27270902 |
ECl@ss 8.1 | 27270902 |
ECl@ss 9.0 | 27270902 |
ETIM 5.0 | EC002717 |
ETIM 6.0 | EC002717 |
UNSPSC 16.0901 | 39121528 |
Smart Task
Smart Task name | Counter + debouncing |
Logic function |
Direct WINDOW Hysteresis |
Timer function |
Deactivated On delay Off delay ON and OFF delay Impulse (one shot) |
Inverter | Yes |
Maximum counting frequency |
SIO Direct: — 1) SIO Logic: 1000 Hz 2) IOL: 900 Hz 3) |
Counter reset |
SIO Direct: — 1) SIO Logic: 1,5 ms 2) IOL: 1,5 ms 3) |
Min. Time between two process events (switches) |
SIO Direct: — SIO Logic: 450 ?s IOL: 500 ?s |
Debounce time max. |
SIO Direct: — SIO Logic: 30.000 ms IOL: 30.000 ms |
Switching signal QL1 | Output type (dependant on the adjusted threshold) |
Switching signal QL2 | Output type (dependant on the adjusted threshold) |
Measuring value | Counting value |
- 1) SIO Direct: sensor operation in standard I/O mode without IO-Link communication and without using internal sensor logic or time parameters (set to “direct”/”deactivated”).2) SIO Logic: Sensor operation in standard I/O mode without IO-Link communication. Sensor-internal logic or timing parameters plus Automation Functions used.3) IOL: Sensor operation with full IO-Link communication and usage of logic, timing and Automation Function parameters.
Communication interface
Communication interface | IO-Link V1.1 |
Communication Interface detail | COM2 (38,4 kBaud) |
Cycle time | 2.3 ms |
Process data length | 16 Bit |
Process data structure |
Bit 0 = switching signal QL1 Bit 1 = switching signal QL2 Bit 2 … 15 = measuring value |