Mô tả sản phẩm
Photoelectric sensors
Sensor/ detection principle | Photoelectric retro-reflective sensor |
Dimensions (W x H x D) | 16 mm x 39.5 mm x 12 mm |
Housing design (light emission) | Rectangular |
Sensing range max. | 0.01 m … 4.5 m 1) |
Sensing range | 0.02 m … 3.5 m 1) |
Type of light | Visible red light |
Light source | PinPoint LED 2) |
Light spot size (distance) | ? 75 mm (1.5 m) |
Wave length | 650 nm |
Adjustment |
Single teach-in button IO-Link |
Pin 2 configuration | External input, Teach-in input, Sender off input, Detection output, logic output, Device contamination alarm output |
Diagnosis | Device contamination monitoring, Quality of teach-in |
AutoAdapt | ? |
Special applications | Detecting transparent objects |
- 1) Reflector PL80A.2) Average service life: 100,000 h at TU = +25 ?C.
Supply voltage | 10 V DC … 30 V DC 1) |
Ripple | < 5 Vpp 2) |
Power consumption | 20 mA 3) |
Switching output | PNP |
Switching mode | Light/dark switching |
Output current Imax. | ? 100 mA |
Response time | < 0.5 ms 4) |
Response time Q/ on Pin 2 | 300 ?s … 450 ?s 4) 5) |
Switching frequency | 1,000 Hz 6) |
Switching frequency Q / to pin 2 | 1,000 Hz 7) |
Angle of reception | Approx. 30? |
Attenuation along light beam | > 8 % |
Connection type | Male connector M8, 4-pin |
Circuit protection |
A 8) C 9) D 10) |
Protection class | III |
Weight | 30 g |
Polarisation filter | ? |
Housing material | Plastic, ABS |
Optics material | Plastic, PMMA |
Enclosure rating |
IP67 IP66 |
Special feature | Detecting transparent objects |
Ambient operating temperature | ?40 ?C … +60 ?C |
Ambient storage temperature | ?40 ?C … +75 ?C |
UL File No. | NRKH.E181493 & NRKH7.E181493 |
Repeatability Q/ on Pin 2: | 150 ?s 5) |
- 1) Limit values.2) May not exceed or fall below Uv tolerances.3) Without load.4) Signal transit time with resistive load.5) Valid for Q on Pin2, if configured with software.6) With light/dark ratio 1:1.7) With light / dark ratio 1:1, valid for Q on Pin2, if configured with software.8) A = VS connections reverse-polarity protected.9) C = interference suppression.10) D = outputs overcurrent and short-circuit protected.
ECl@ss 5.0 | 27270902 |
ECl@ss 5.1.4 | 27270902 |
ECl@ss 6.0 | 27270902 |
ECl@ss 6.2 | 27270902 |
ECl@ss 7.0 | 27270902 |
ECl@ss 8.0 | 27270902 |
ECl@ss 8.1 | 27270902 |
ECl@ss 9.0 | 27270902 |
ETIM 5.0 | EC002717 |
ETIM 6.0 | EC002717 |
UNSPSC 16.0901 | 39121528 |
Smart Task name | Time measurement + debouncing |
Logic function |
Direct WINDOW |
Timer function |
Deactivated On delay Off delay ON and OFF delay Impulse (one shot) |
Inverter | Yes |
Time measurement accuracy |
SIO Direct: — SIO Logic: – 0,7 … + 0,7 ms ? 0,5 % of time measurement value IOL: – 0.9 … + 0.9 ms ? 0.5% of the time measurement |
Time measurement accuracy (e.g. accuracy for time measurement value = 1 s ) |
SIO Direct: — SIO Logic: – 5,7 … + 5,7 ms IOL: – 5,9 … + 5,9 ms |
Resolution time measuring value | 1 ms |
Min. Time between two process events (switches) |
SIO Direct: — 1) SIO Logic: 450 ?s 2) IOL: 500 ?s 3) |
Debounce time max. |
SIO Direct: — SIO Logic: 30.000 ms IOL: 30.000 ms |
Switching signal QL1 | Output type (dependant on the adjusted threshold) |
Switching signal QL2 | Output type (dependant on the adjusted threshold) |
Measuring value | Time measurement value |
- 1) SIO Direct: sensor operation in standard I/O mode without IO-Link communication and without using internal sensor logic or time parameters (set to “direct”/”deactivated”).2) SIO Logic: Sensor operation in standard I/O mode without IO-Link communication. Sensor-internal logic or timing parameters plus Automation Functions used.3) IOL: Sensor operation with full IO-Link communication and usage of logic, timing and Automation Function parameters.
Communication interface | IO-Link V1.1 |
Communication Interface detail | COM2 (38,4 kBaud) |
Cycle time | 2.3 ms |
Process data length | 16 Bit |
Process data structure |
Bit 0 = switching signal QL1 Bit 1 = switching signal QL2 Bit 2 … 15 = measuring value |