Mô tả sản phẩm
Photoelectric sensors
Features
Sensor/ detection principle | Photoelectric retro-reflective sensor, autocollimation |
Dimensions (W x H x D) | 15.25 mm x 48.6 mm x 22.15 mm |
Housing design | Hygiene |
Housing design (light emission) | Rectangular |
Sensing range max. | 0 m … 5 m 1) |
Sensing range | 0 m … 3 m 1) |
Type of light | Visible red light |
Light source | PinPoint LED 2) |
Light spot size (distance) | ? 45 mm (1.5 m) |
Wave length | 650 nm |
Adjustment |
IO-Link Single teach-in button |
AutoAdapt | ? |
Special applications | Detecting transparent objects, Hygienic and washdown zones |
- 1) Reflector PL80A.2) Average service life: 100,000 h at TU = +25 ?C.
Mechanics/electronics
Supply voltage | 10 V DC … 30 V DC 1) |
Ripple | < 5 Vpp 2) |
Power consumption | 30 mA 3) |
Switching output | PNP |
Switching mode | Light switching |
Output current Imax. | ? 100 mA |
Response time Q/ on Pin 2 | 300 ?s … 450 ?s 4) 5) |
Switching frequency | 1,000 Hz |
Switching frequency Q / to pin 2 | 1,000 Hz 6) |
Connection type | Cable with M8 male connector, 4-pin, 150 mm |
Circuit protection | A, B, C 10) 7) 8) 9) |
Protection class | III |
Weight | 50 g |
Polarisation filter | ? |
IO-Link | ? |
Special device | ? |
Housing material | Stainless steel, Stainless steel V4A (1.4404, 316L) |
Enclosure rating |
IP66 IP67 IP68 IP69K |
Special feature | Detecting transparent objects |
Ambient operating temperature | ?30 ?C … +60 ?C 11) |
Ambient storage temperature | ?30 ?C … +75 ?C |
UL File No. | FDA, UL No. NRKH.E181493 & cUL No. NRKH7.E181493 |
Repeatability Q/ on Pin 2: | 150 ?s |
- 1) Limit values when operated in short-circuit protected network: max. 8 A.2) May not exceed or fall below Uv tolerances.3) Without load.4) Signal transit time with resistive load.5) Valid for Q on Pin2, if configured with software.6) With light / dark ratio 1:1, valid for Q on Pin2, if configured with software.7) A = VS connections reverse-polarity protected.8) B = inputs and output reverse-polarity protected.9) C = interference suppression.10) D = outputs overcurrent and short-circuit protected.11) At UV ? 24 V and IA < 30 mA.
Classifications
ECl@ss 5.0 | 27270902 |
ECl@ss 5.1.4 | 27270902 |
ECl@ss 6.0 | 27270902 |
ECl@ss 6.2 | 27270902 |
ECl@ss 7.0 | 27270902 |
ECl@ss 8.0 | 27270902 |
ECl@ss 8.1 | 27270902 |
ECl@ss 9.0 | 27270902 |
ETIM 5.0 | EC002717 |
ETIM 6.0 | EC002717 |
UNSPSC 16.0901 | 39121528 |
Smart Task
Switching frequency |
SIO Direct: 1000 Hz SIO Logic: 1000 Hz IOL: 900 Hz |
Repeatability |
SIO Direct: 150 ?s 1) SIO Logic: 150 ?s 2) IOL: 300 ?s 3) |
- 1) SIO Direct: sensor operation in standard I/O mode without IO-Link communication and without using internal sensor logic or time parameters (set to “direct”/”deactivated”).2) SIO Logic: Sensor operation in standard I/O mode without IO-Link communication. Sensor-internal logic or timing parameters plus Automation Functions used.3) IOL: Sensor operation with full IO-Link communication and usage of logic, timing and Automation Function parameters.