Mô tả sản phẩm
Fiber-optic sensors and fibers
Features
Device type | Base unit 1) |
Dimensions (W x H x D) | 10.5 mm x 34.6 mm x 71.9 mm |
Housing design (light emission) | Rectangular |
Sensing range max. | 0 m … 20 m, Through-beam system 2) 3) |
Sensing range |
0 mm … 1,400 mm, Proximity system 4) 5) 0 … 18 m, Through-beam system 2) 3) |
Focus | 6) |
Type of light | Visible red light |
Light source | LED 7) |
Angle of dispersion | Approx. 65? 6) |
Wave length | 650 nm |
Adjustment |
Menu-controlled Single teach-in button Cable |
Time type |
Without time delay Off delay On delay ON and OFF delay One shot |
Delay time | Programmable, 0 ms, 9,999 ms |
Indication | Display |
Display | LED status display / 2x 4-character digital dual displays, Set value (green indicator) and actual value (red indicator) are displayed simultaneously, display of parameters |
- 1) Up to 15 expansion units can be connected.2) Sensing range with 8 ms response time. Reduction with shorter response time (see tables LL3/WLL180T).3) LL3-TX01.4) Objects to be sensed with 90% reflectivity (based on DIN 5033 white standard). Sensing range with 8 ms response time. Reduction with shorter response time (see tables LL3/WLL180T).5) LL3-DK06.6) See LL3 fiber-optic data.7) Average service life: 100,000 h at TU = +25 ?C.
Mechanics/electronics
Supply voltage | 12 V DC … 24 V DC 1) |
Ripple | ? 10 % 2) |
Power consumption | 50 mA 3) |
Switching output | NPN |
Number of switching outputs | 1 |
Switching mode | Light/dark switching |
Switching mode selector | Manually selectable |
Output current Imax. | ? 100 mA |
Response time | ? 16 ?s, ? 70 ?s, ? 250 ?s, ? 2,000 ?s, ? 8,000 ?s 4) |
Switching frequency |
31.2 kHz 7.1 kHz 2 kHz 250 Hz 62.5 Hz |
Input | Multifunctional input MF |
Connection type | Cable, 4-wire, 2 m 5) |
Cable material | PVC |
Conductor cross-section | 0.2 mm? |
Circuit protection |
A 6) B 7) C 8) D 9) |
Protection class | III |
Weight | 25 g |
Housing material | Plastic, ABS/PC |
Enclosure rating | IP50 10) |
Items supplied | BEF-WLL180 mounting bracket |
Ambient operating temperature | ?25 ?C … +55 ?C |
Ambient storage temperature | ?40 ?C … +70 ?C |
UL File No. | NRKH.E300503 |
- 1) +- 10%.2) May not exceed or fall below Uv tolerances.3) Without load.4) Selectable.5) Do not bend below 0 ?C.6) A = VS connections reverse-polarity protected.7) B = inputs and output reverse-polarity protected.8) C = interference suppression.9) D = outputs overcurrent and short-circuit protected.10) With correctly attached fibre-optic cable LL3 and closed protection hood.
Classifications
ECl@ss 5.0 | 27270905 |
ECl@ss 5.1.4 | 27270905 |
ECl@ss 6.0 | 27270905 |
ECl@ss 6.2 | 27270905 |
ECl@ss 7.0 | 27270905 |
ECl@ss 8.0 | 27270905 |
ECl@ss 8.1 | 27270905 |
ECl@ss 9.0 | 27270905 |
ETIM 5.0 | EC002651 |
ETIM 6.0 | EC002651 |
UNSPSC 16.0901 | 39121528 |