Features
Device type Stand-alone
Sensor/ detection principle Fiber-optic photoelectric sensor
Dimensions (W x H x D) 10.5 mm x 34.8 mm x 76.5 mm
Housing design (light emission) Rectangular
Sensing range max. 0 m … 4 m, Through-beam system 1) 2)
Sensing range

0 mm … 160 mm, Proximity system 3) 4)

0 m … 900 mm, Through-beam system 5)

Focus 6)
Type of light Visible green light
Light source LED 7)
Angle of dispersion Approx. 65? 6)
Wave length 525 nm
Adjustment

Menu-controlled

Single teach-in button

Cable

Time type

Without time delay

Off delay

On delay

One shot

Delay time Programmable, 0 ms, 9,999 ms
Indication Display
Display LED status display / 2x 4-character digital dual displays, Set value (green indicator) and actual value (red indicator) are displayed simultaneously, display of parameters
    1) Sensing range at response time 2 ms. Reduction at shorter response time (see LL3/ WLL190T-2 table).2) LL3-TB02 and tip adapter LL3-TA01.3) Object with 90% remission (based on standard white DIN 5033). Sensing range with 2 ms response time. Reduction for shorter response time (see tables LL3/WLL190T-2).4) LL3-DB01.5) LL3-TB01.6) See LL3 fiber-optic data.7) Average service life: 100,000 h at TU = +25 ?C.
Mechanics/electronics
Supply voltage 10 V DC … 24 V DC 1)
Ripple ? 10 % 2)
Power consumption ? 50 mA
Switching output PNP 3) 4)
Switching mode Light/dark switching 3) 4)
Switching mode selector Manually selectable
Output current Imax. ? 100 mA
Response time ? 2 ms, ? 60 ?s, ? 250 ?s
Switching frequency

8,333 Hz

2,000 Hz

250 Hz

Connection type Male connector M8, 4-pin
Circuit protection

A 5)

B 6)

C 7)

D 8)

Protection class III
Weight 25 g
Housing material Plastic, ABS/PC
Enclosure rating IP66 9)
Ambient operating temperature ?25 ?C … +55 ?C 10)
Ambient storage temperature ?40 ?C … +70 ?C
    1) +- 10%.2) May not exceed or fall below Uv tolerances.3) Q1, Q2.4) Selectable Q2, external teach or counter reset.5) A = VS connections reverse-polarity protected.6) B = inputs and output reverse-polarity protected.7) C = interference suppression.8) D = outputs overcurrent and short-circuit protected.9) With correctly attached fibre-optic cable LL3 and closed protection hood.10) Operating temperature fluctuates according to number of devices connected: 4?8 devices: ?25 ?C … +50 ?C (output current 50 mA) / 9?16 devices: ?25 ?C … +45 ?C (output current 20 mA).