WSE4SLC-3P2236A00

8,736,000

Tên sản phẩm: Miniature photoelectric sensors W4SL-3

Danh mục: Photoelectric sensors

Model: WSE4SLC-3P2236A00

ID: 1080957

Nhà sản xuất: SICK

Xuất xứ: DE

Hàng mới 100%, bảo hành 12 tháng theo quy định nhà sản xuất

Cung cấp chứng nhận xuất xứ (CO), chứng nhận chất lượng (CQ) theo yêu cầu khách hàng

Mã: 1080957 Danh mục:

Mô tả sản phẩm

Photoelectric sensors

Features
Sensor/ detection principle Through-beam photoelectric sensor
Dimensions (W x H x D) 12.2 mm x 41.8 mm x 17.3 mm
Housing design (light emission) Rectangular
Mounting hole M3
Sensing range max. 0 m … 60 m
Sensing range 0 m … 50 m
Type of light Visible red light
Light source Laser 1)
Light spot size (distance) ? 1 mm (500 mm)
Wave length 650 nm
Laser class 1 (EN 60825-1:2014, IEC 60825-1:2014 / CDRH 21 CFR 1040.10 & 1040.11)
Adjustment IO-Link
Pin 2 configuration External input, Detection output, logic output, alarm output operating reserve
Diagnosis Status indicator operating reserve
Special applications Detecting small objects
    1) Average service life: 50,000 h at TU = +25 ?C.
Mechanics/electronics
Supply voltage 10 V DC … 30 V DC 1)
Ripple < 5 Vpp 2)
Power consumption 30 mA 3)
Switching output PNP 4)
Output function Complementary
Switching mode Light/dark switching 4)
Output current Imax. ? 100 mA
Response time ? 0.5 ms 5)
Switching frequency 1,000 Hz 6)
Switching frequency Q / to pin 2 1,000 Hz 7)
Connection type Male connector M8, 4-pin
Circuit protection

A 8)

B 9)

C 10)

Protection class III
Weight 100 g
Housing material Plastic, Novodur
Optics material Plastic, PMMA
Enclosure rating

IP66

IP67

Ambient operating temperature ?10 ?C … +50 ?C
Ambient operating temperature extended ?30 ?C … +55 ?C 11) 12)
Ambient storage temperature ?30 ?C … +70 ?C
MTTFd: mean time to dangerous failure 355 years (EN ISO 13849-1) 13)
Part number of individual components 2064095 WS4SL-3D2236, 2088186 WE4SLC-3P2230A00
Repeatability Q/ on Pin 2: 150 ?s 14)
    1) Limit values when operated in short-circuit protected network: max. 8 A.2) May not exceed or fall below Uv tolerances.3) Without load.4) Q = light switching.5) Signal transit time with resistive load.6) With light/dark ratio 1:1.7) With light / dark ratio 1:1, valid for Q on Pin2, if configured with software.8) A = VS connections reverse-polarity protected.9) B = inputs and output reverse-polarity protected.10) C = interference suppression.11) As of Ta = 50 ?C, a max. supply voltage Vmax. = 24 V and a max. load current Imax. = 50 mA is permitted.12) Operation below Tu ?10 ?C is possible if the sensor is already switched on at Tu > ?10 ?C, then cools down, and the supply voltage is subsequently not switched off. Switching on below Tu ?10 ?C is not permissible.13) Mode of calculation: Parts-Count-calculation.14) Valid for Q on Pin2, if configured with software.
Classifications
ECl@ss 5.0 27270901
ECl@ss 5.1.4 27270901
ECl@ss 6.0 27270901
ECl@ss 6.2 27270901
ECl@ss 7.0 27270901
ECl@ss 8.0 27270901
ECl@ss 8.1 27270901
ECl@ss 9.0 27270901
ETIM 5.0 EC002716
ETIM 6.0 EC002716
UNSPSC 16.0901 39121528
Smart Task
Smart Task name Base logics
Logic function

Direct

AND

OR

Hysteresis

Timer function

Deactivated

On delay

Off delay

ON and OFF delay

Impulse (one shot)

Inverter Yes
Switching frequency

SIO Direct: 1000 Hz 1)

SIO Logic: 1000 Hz 2)

IOL: 900 Hz 3)

Response time

SIO Direct: 300 ?s … 450 ?s 1)

SIO Logic: 500 ?s … 600 ?s 2)

IOL: 500 ?s … 900 ?s 3)

Repeatability

SIO Direct: 150 ?s 1)

SIO Logic: 150 ?s 2)

IOL: 400 ?s 3)

Switching signal QL1 Switching output
Switching signal QL2 Switching output
    1) SIO Direct: sensor operation in standard I/O mode without IO-Link communication and without using internal sensor logic or time parameters (set to “direct”/”deactivated”).2) SIO Logic: Sensor operation in standard I/O mode without IO-Link communication. Sensor-internal logic or timing parameters plus Automation Functions used.3) IOL: Sensor operation with full IO-Link communication and usage of logic, timing and Automation Function parameters.
Communication interface
Communication interface IO-Link V1.1
Communication Interface detail COM2 (38,4 kBaud)
Cycle time 2.3 ms
Process data length 16 Bit
Process data structure

Bit 0 = switching signal QL1

Bit 1 = switching signal QL2

Bit 2 … 15 = empty