WTB4SC-3P3232S10

5,555,000

Tên sản phẩm: Miniature photoelectric sensors W4S-3

Danh mục: Photoelectric sensors

Model: WTB4SC-3P3232S10

ID: 1079436

Nhà sản xuất: SICK

Xuất xứ: DE

Hàng mới 100%, bảo hành 12 tháng theo quy định nhà sản xuất

Cung cấp chứng nhận xuất xứ (CO), chứng nhận chất lượng (CQ) theo yêu cầu khách hàng

Mã: 1079436 Danh mục:

Mô tả sản phẩm

Photoelectric sensors

Features
Sensor/ detection principle Photoelectric proximity sensor, Background suppression
Dimensions (W x H x D) 12.2 mm x 41.8 mm x 17.3 mm
Housing design (light emission) Rectangular
Sensing range max. 4 mm … 280 mm 1)
Sensing range 10 mm … 150 mm 1)
Type of light Visible red light
Light source PinPoint LED 2)
Light spot size (distance) ? 6.5 mm (150 mm)
Wave length 650 nm
Adjustment

IO-Link

Single teach-in button

Special features Sensing range: preset 104 mm
    1) Object with 90 % reflectance (referred to standard white, DIN 5033).2) Average service life: 100,000 h at TU = +25 ?C.
Mechanics/electronics
Supply voltage 10 V DC … 30 V DC 1)
Ripple < 5 Vpp 2)
Power consumption 30 mA 3)
Switching output PNP
Switching mode Light/dark switching
Output current Imax. ? 100 mA
Response time Q/ on Pin 2 280 ?s … 410 ?s 4)
Switching frequency 1,000 Hz
Switching frequency Q / to pin 2 1,000 Hz 5)
Connection type Cable with M8 male connector, 4-pin, 100 mm
Cable material PVC
Conductor cross-section 0.14 mm?
Cable diameter ? 3.4 mm
Circuit protection

A 6)

B 7)

C 8)

D 9)

Protection class III
Weight 20 g
IO-Link ?
Transmission rate COM2
Housing material Plastic, ABS
Optics material PMMA
Enclosure rating

IP67

IP66

Ambient operating temperature ?40 ?C … +60 ?C
Ambient storage temperature ?40 ?C … +75 ?C
UL File No. NRKH.E181493 & NRKH7.E181493
Repeatability Q/ on Pin 2: 130 ?s 10)
    1) Limit values when operated in short-circuit protected network: max. 8 A.2) May not exceed or fall below Uv tolerances.3) Without load.4) Signal transit time with resistive load.5) With light / dark ratio 1:1, valid for Q on Pin2, if configured with software.6) A = VS connections reverse-polarity protected.7) B = inputs and output reverse-polarity protected.8) C = interference suppression.9) D = outputs overcurrent and short-circuit protected.10) Valid for Q on Pin2, if configured with software.
Classifications
ECl@ss 5.0 27270904
ECl@ss 5.1.4 27270904
ECl@ss 6.0 27270904
ECl@ss 6.2 27270904
ECl@ss 7.0 27270904
ECl@ss 8.0 27270904
ECl@ss 8.1 27270904
ECl@ss 9.0 27270904
ETIM 5.0 EC002719
ETIM 6.0 EC002719
UNSPSC 16.0901 39121528
Smart Task
Switching frequency

SIO Direct: 1000 Hz

SIO Logic: 900 Hz

IOL: 700 Hz

Repeatability

SIO Direct: 130 ?s 1)

SIO Logic: 130 ?s 2)

IOL: 310 ?s 3)

    1) SIO Direct: sensor operation in standard I/O mode without IO-Link communication and without using internal sensor logic or time parameters (set to “direct”/”deactivated”).2) SIO Logic: Sensor operation in standard I/O mode without IO-Link communication. Sensor-internal logic or timing parameters plus Automation Functions used.3) IOL: Sensor operation with full IO-Link communication and usage of logic, timing and Automation Function parameters.