Mô tả sản phẩm
Photoelectric sensors
Features
Sensor/ detection principle | Photoelectric proximity sensor, Background suppression |
Dimensions (W x H x D) | 15.3 mm x 63.2 mm x 22.2 mm |
Housing design | Hygiene 1) |
Housing design (light emission) | Rectangular |
Mounting hole | M3 |
Sensing range max. | 25 mm … 300 mm 2) |
Sensing range | 25 mm … 300 mm 2) |
Type of light | Visible red light |
Light source | Laser 3) |
Light spot size (distance) | ? 1 mm (170 mm) |
Wave length | 650 nm |
Laser class | 1 (EN 60825-1:2014, IEC 60825-1:2014 / CDRH 21 CFR 1040.10 & 1040.11) |
Adjustment | Single teach-in button |
Special applications | Hygienic and washdown zones, Detecting small objects |
- 1) Difference between standard/washdown and hygiene: The essential difference between a standard/washdown product and a hygiene product is that where the process and contact with the medium (activity in the vicinity of the food) are concerned, a hygiene product is designed in accordance with the latest standards and hygiene design guidelines, and materials are selected accordingly.2) Object with 90 % reflectance (referred to standard white, DIN 5033).3) Average service life: 50,000 h at TU = +25 ?C.
Mechanics/electronics
Supply voltage | 10 V DC … 30 V DC 1) |
Ripple | < 5 Vpp 2) |
Power consumption | 30 mA 3) |
Switching output | PNP 4) |
Output function | Complementary |
Switching mode | Light/dark switching 4) |
Output current Imax. | ? 100 mA |
Response time | ? 0.5 ms 5) |
Switching frequency | ? 1,000 Hz 6) |
Connection type | Cable, 4-wire, 2 m 7) |
Mechanical connection | D12 adapter shaft |
Cable material | PVC |
Conductor cross-section | 0.14 mm? |
Circuit protection |
A 8) B 9) C 10) |
Protection class | III |
Weight | 180 g |
Housing material | Stainless steel, Stainless steel V4A (1.4404, 316L) |
Optics material | Plastic, PMMA |
Enclosure rating |
IP66 IP67 IP68 IP69K 11) |
Special feature | D12 adapter shaft |
Ambient operating temperature | ?10 ?C … +50 ?C |
Ambient operating temperature extended | ?30 ?C … +55 ?C 12) 13) |
Ambient storage temperature | ?30 ?C … +70 ?C |
- 1) Limit values when operated in short-circuit protected network: max. 8 A.2) May not exceed or fall below Uv tolerances.3) Without load.4) Q = light switching.5) Signal transit time with resistive load.6) With light/dark ratio 1:1.7) Do not bend below 0 ?C.8) A = VS connections reverse-polarity protected.9) B = inputs and output reverse-polarity protected.10) C = interference suppression.11) Only in case of correctly mounted IP69K connecting cable.12) As of Ta = 50 ?C, a max. supply voltage Vmax. = 24 V and a max. load current Imax. = 50 mA is permitted.13) Operation below Tu ?10 ?C is possible if the sensor is already switched on at Tu > ?10 ?C, then cools down, and the supply voltage is subsequently not switched off. Switching on below Tu ?10 ?C is not permissible.
Classifications
ECl@ss 5.0 | 27270904 |
ECl@ss 5.1.4 | 27270904 |
ECl@ss 6.0 | 27270904 |
ECl@ss 6.2 | 27270904 |
ECl@ss 7.0 | 27270904 |
ECl@ss 8.0 | 27270904 |
ECl@ss 8.1 | 27270904 |
ECl@ss 9.0 | 27270904 |
ETIM 5.0 | EC002719 |
ETIM 6.0 | EC002719 |
UNSPSC 16.0901 | 39121528 |